Place the tip of the needle in the liquid. Slowly draw up a small amount of liquid by raising the plunger, then press on the plunger to expel the liquid back into the liquid. This serves to “rinse" the syringe with your sample, ensuring that what you will measure in the GC run is the composition of your mixture. Repeat the rinse
8 Jun 2015 GOW-MAC 350 series and 400 series Thermal Conductivity Gas Chromatograph There are 2 manuals for the GCs, one for the DACS Strip Chart Software that runs on the PC and one for the Gas Chromatograph itself. The 400 is more reliable in that the column temperature stays where it is set. The 350
SB-400. Series 400. Isothermal. Gas Chromatograph. Optional Microscale Preparative Techniques. The use of microscale preparative techniques in the organic chemistry laboratory has The GOW-MAC® Series 400 Isothermal, Thermal Conductivity. Detector Optional manual gas sample valves available. Detector
An operating manual for your particular GOW-MAC instrument may be purchased from GOW-MAC by calling our sales department at (610) 954-9000 (USA), +886-3-5422845 (Taiwan), or +86-13-501010846 (China). When calling, please have ready the instrument's complete model number and serial number. Both are
Isothermal Operation; Detector: Thermal Conductivity Detector (TCD); Direct On-Column Injection or Gas Sample Valve (manual or pneumatic); Single or Dual Column; Microscale Compatible: heated The GOW-MAC Series 400MGA Medical Gas Analyzer is a gas chromatograph with a thermal conductivity detector (TCD).
The GOW-MAC Series 580 Gas Chromatograph sets the standard for reliable performance in a wide range of manually by syringe or automatically via autosampler or liquid sampling valves. Flow Systems to 400°C. Temperature controls for injection ports, column oven, and detector are solid state proportioning type with
They meet the demands for teaching the principles of gas chromatography, chemistry and biochemistry. In January 2005, the Series 400 GCs replaced our very popular Series 350 GCs. Isothermal Operation; Detector: Thermal Conductivity Detector (TCD); Direct On-Column Injection or Gas Sample Valve (manual or
GENERAL The GOW-MAC Model 69-150 Fundamental Gas Chromatograph has been designed to meet the need for a small~ inexpensive. . Thermtll with CONDITIONS Conductivity Cells RHENIUM -TUNGSTEN FI LAM ENTS (WX or W2X) 500 a 101 . sao o 100 200 CELL 300 ·C 400 TEMPERATURE Figure 3 -8- .
Operation of the GOWMAC Series 350 Gas Chromatograph. 1. Turn on the chart recorder. Turn the "DET your lab manual. 6. If necessary, you may clean the syringe by filling and emptying it with your sample two or three times. 7. Fill the syringe with your sample. About 1 :L is recommended at first. Ensure that you do have
The Series 400 and 400-P Isothermal, Thermal Conductivity Detector (TCD) Gas Chromatographs are rugged, compact, affordable, service-free GCs designed for high capability performance while withstanding rough, student or industrial use. They meet the demands for teaching the principles of gas chromatography,