Tuesday 20 February 2018 photo 5/14
|
Carel controller ir33 manual: >> http://zak.cloudz.pw/download?file=carel+controller+ir33+manual << (Download)
Carel controller ir33 manual: >> http://zak.cloudz.pw/read?file=carel+controller+ir33+manual << (Read Online)
carel ir manual
carel ir33 fault codes
carel ir33+ manual
carel ir32 manual
carel ir33 universal manual
ir33 carel
carel ir33 wiring diagram
carel easy controller parameters
14 Jul 2009 ir33 smart is now ready to be configured. For correct ir33 smart - IR33S7HR0E Electronic controller for normal and high temperature static refrigeration units SUPPLY. Inputs. Room probe. NTC 1. Outputs. Compressor. R1: 16 A relay. Main parameters. (type F). Name. Type. Description. Default value. St.
Code Parameter. Unit Type Min. Max. Def. New. St1 Set point 1. °C/°F. F c21 c22. 20. St2 Set point 2. °C/°F. F c23 c24. 40 c0. Operating mode (ie heating, cooling, alarm) -. C. 0. 9. 2. 1 = all outputs direct (cooling), 2 = all outputs reverse (heating),. 3 = 1/2 outputs direct 1/2 reverse (cooling and heating),. 4 = pulse with
17 Mar 2010 All modifications made to the parameters, temporarily stored into the internally memory of the controller, can be cancelled and normal operation resumed by not pressing any button for 60 second, thus allowing the parameter setting session to expire due to timeout
ir33 is the basic complete set of controls selection offered by CAREL for applications in refrigeration.
Do not use the product for applications other than those specified in the technical manual. All of the above suggestions likewise apply to the controllers, serial boards, programming keys or any other accessory in the. CAREL product portfolio. CAREL adopts a policy of continual development. Consequently, CAREL reserves
Warning! Save Your Parameter Settings! 1. To store the new parameter values, PRESS and HOLD the “Prg" key for at least 5 seconds. 2. All modifications made to parameters will be lost if you do NOT press a button within 60 seconds. Should this “timeout" occur, normal operational settings (prior to modifications being
CAREL. 7. PARAMETER TABLE. Default settings table. Key: Parameter type: Variable type: 0 Noted: C = Con?guration, A : analogue, - MSYFCH = parameter visible on models F : frequent I: integer, - The grey rows in the table denote masked parameters .. The EE/EF data memory alarms shutdown the controller.
technical manual. All of the above suggestions likewise apply to the controllers, serial boards, programming keys or any other accessory in the CAREL product portfolio. CAREL adopts a policy of continual development. Consequently, CAREL reserves the right to make changes and improvements to any product described
The alarm relay is enabled if one of the auxiliary 1 and auxiliary 2 outputs (“H1" and “H5") has been given the function of alarm relay (normally closed or open). Nota: the buzzer is disabled if the controller is connected to the CAREL supervisory system. /A2/A4: Probe configuration. Allows configuring the operation mode of
27 Mar 2013 technical manual. All of the above suggestions likewise apply to the controllers, serial boards, programming keys or any other accessory in the CAREL .. ir33+;. • ir33+ wide and ir33+ small wide;. • easy wide and easy small wide. which share the same software and differ in terms of shape, user interface.