Sunday 4 March 2018 photo 8/15
|
Balluff btl5 e17 manuals: >> http://rbh.cloudz.pw/download?file=balluff+btl5+e17+manuals << (Download)
Balluff btl5 e17 manuals: >> http://rbh.cloudz.pw/read?file=balluff+btl5+e17+manuals << (Read Online)
balluff micropulse btl5-e17
balluff btl5-a11
balluff micropulse linear transducer
balluff btl5 calibration
balluff btl2 manual
balluff btl5-p1
balluff micropulse wiring
balluff btl5-e10
BTL5-P/I/K/L/M_-M/U_ _ _ _-P-S32/KA_ _. Micropulse Linear Transducer. Digital Output / Profile Housing. Read this manual before installing and operating the Micropulse. Transducer. 1.1 Proper application. The BTL5 Micropulse transducer is intended to be installed in a machine or system. Together with a controller (PLC)
11.7 Accessories .. 12. 12 Versions (indicated on product label) . 12. Read this manual before installing and operating the Micropulse Trans- ducer. 1.1. Proper application. The BTL5 Micropulse transducer is intended to be installed in a ma- chine or system. Together with a controller (PLC) it comprises
BTL5-A/C/E/G1_-M/U_ _ _ _-K-SR 32/K_ _. Micropulse Linear Transducer - Rod Style. 2 english. Read this manual before installing and operating the Micropulse trans- ducer. 1.1. Proper application. The BTL5 Micropulse transducer is intended to be installed in a ma- chine or system. Together with a controller (PLC) or a
BTL5-A/C/E/G1_-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _. Micropulse Linear . Read this manual before install- ing and operating the .. WH. BTL5-C/EK_ _. Output signals. Wire color. BTL5-A11 -C10 -C17 -E10 -E17 -G11. YE yellow not used. 020 mA 200 mA 420 mA 204 mA not used. PK pink. 100 V. 100 V.
www.balluff.com. 9 english. Electrical connection. 4.2. The electrical connection is permanent and made using a cable (F_ _). The connection assignments depend on the respective model (see Tab. 4-1). Output signals. Cable. BTL5-A11. -C10. -C17. -E10. -E17. YE. Yellow. Not used2). 0 to 20 mA. 20 to 0 mA. 4 to 20 mA.
Output Signal. RS422/RS485 Start/Stop Pulse. Resolution. Controller dependent. Non-linearity. Stroke length ? 500 mm = +/- 100 µm. Stroke length > 500 mm = 0.02% of full scale. Hysteresis. 5 µm. Sampling Rate. Controller dependent, 0.5 ms minimum. Operating Voltage. +24 Vdc +/- 20%. Current Draw. ? 150 mA.
BTL5-A/C/E/G1 _-M_ _ _ _-HB/WB-FA_ _/F_ _-C. Micropulse Linear Transducer - Rod Style english. 2. Read this manual before installing and operating the Micropulse Trans- ducer. 1.1. Proper application. The BTL5 Micropulse transducer is intended to be installed in a ma- chine or system. Together with a controller (PLC)
Read this manual before installing and operating the Micropulse. Transducer. 1.1 Proper application. The BTL5 Micropulse transducer is intended to be installed in a machine or system. Together with a controller (PLC) or a processor. (BTA) it comprises a position measuring system and may only be used for this purpose.
BTL5-S1_ _-M_ _ _ _-HB/WB-FA_ _/F_ _-C. Micropulse Linear Transducer - Rod Style. 1 english. User's Manual. Balluff GmbH. Schurwaldstra?e 9. 73765 Neuhausen a.d.F.. Germany. Phone +49 7158 173-0. Fax +49 7158 5010 balluff@balluff.de www.balluff.com
Binder. Bild 4-3: Steckverbinder (optional). Kabeldurchlass (Klemmkorb PG 9). Ausgangssignale. Pin Kabel. BTL5-A11. -C10. -C17. -E10. -E17. -G11. 1. YE gelb Manual adjust. This method allows you to set a new start and/or end value. This may be useful if the magnet can not be brought to the null or end point.
Annons