Volume 14. DirectSOFT5 for DirectLOGIC PLCs. DirectSOFT5 makes relay ladder logic easy and fast. We have taken the guesswork out of everyday program- ming with IBox instructions. The IBox instructions are intel- ligent modularized instructions that perform simple to complex ladder logic. If you need to set up an Analog.
12--5. RLLPLUS Instruction Set. Stage Instructions. DL305 User Manual, Rev. D. The Jump instruction allows the program to transition from an active stage which 1. ENT. ENT. ENT. ENT. 2. ENT. ENT. SG. SHF. JMP. SHF. 1. OUT. SHF. 5. STR. ENT. 0. ENT. 2. ENT. Handheld Programmer Keystrokes. DirectSOFT Display
CLICK Instruction Set. Instructions. Normally Open Contact. The Normally Open Contact mimics the behavior of a physical contact and changes in response to the status of a Bit Memory The Set instruction turns ON the associated Bit Memory when the sta- . NOTE: CLICK PLCs cannot be programmed using DirectSOFT5.
Boolean Instructions. 2. Timer Instructions. 3. Counter Instructions. 4. Shift Register Instruction. 5. Accumulator Instructions. Detailed examples of all categories of instructions are included in Chapters 11 & 12. The DL305 CPUs can be programmed with the DirectSOFT PC-based programming package, or by using the
chart to indicate how the instruction is used with DirectSOFT 5 and the HPP. The following paragraphs show how these Set (SET). The Set instruction sets or turns on an image register point/memory location or a consecutive range of image register points/memory locations. Once the point/ location is set it will remain on
Global. GX. 0--777. 0--1777. 0--2777 (GX + GY). * Timer and counter operand data types are not valid using the Set instruction. In the following example when X1 turns on, Y5 through Y22 will be set to the on state. STR. X(IN). 1. SET. Y(OUT). 5. Y(OUT). 2. 2. SET. X1. Y5. Y22. Handheld Programmer Keystrokes. DirectSOFT.
Master Line Set. 5–185. MOV. Move. 5–144. MOVMC. Move Memory Cartridge. 5–145. MRX. Read from MODBUS Network 5–205. MWX. Write to MODBUS. 5–208 . Output or, OUT instruction. The following example shows how to enter a single contact and a single output coil. OUT. Y0. X0. END. DirectSOFT Example.
familiarize you with the instruction sets of the CPUs . Please refer to the applicable PLC user manual for the RLL instructions . The Quick Start chapter will show the first time user how to get started using DirectSOFT 6 . The balance of the manual will detail all of the programming tools made available to the user . Who Can
11--5. Instruction Set. Boolean Instructions. DL305 User Manual, Rev. D. The Store Timer instruction begins a new rung or additional branch in a rung with a 5. ENT. OUT. CNT. SHF. 6. Handheld Programmer Keystrokes. DirectSOFT Display. In the following Store Not Counter example, when the current value in counter
10--5. RLLPLUS Programming Basics. DL305 User Manual, Rev. D. An RLLPLUS Solution. The RLLPLUS instructions keep the simplicity of the contacts and coils .. SET. SG. S150. Stop. S0 -- S6. RST. 010. Monitor for stop. S0. JMP. 020 -- 022. RST. We did not absolutely have to use a SET instruction in the example.