L8124 Aquastat® Relays provide high limit, low limit, and circulator control for maintaining boiler temperatures. • L8124 Aquastat Relays can provide multizone control by using a separate circulator and R845 Relay for each zone. • All L8124 Aquastat Relays mount directly on the boiler. • L8124E,G and L have large
L8124 Models and Applications. a Multizone control can be provided using a separate circulator and R845 Relay for each zone. b Contacts are not powered; rated for switching of millivoltage loads. These Aquastat® Relays have a diaphragm powerhead and Micro Switch Assembly that respond to temperature changes in
Built to last. Meet all your immersion-type hydronic controller needs for years to come with the Honeywell L8124A/C and. L8148A Aquastat® relays. For high-limit, low-limit and circulator control that maintains boiler temperatures efficiently and effectively, the reliable L8124A/C and L8148A relays have you covered without
Info & Guides. Instructions / Assembly · Specification. You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site. Info & Guides
MAXIMUM AMBIENT TEMPERATURE: 150°F (66°C) at case. 265°F (130°C) at sensing element. PRESSURE RATING: 200 psi (1380 kPa) on outside of immersion well. THERMOSTAT HEAT ANTICIPATOR SETTING: 0.2A. LOW LIMIT (Fig. 2):. Function: Maintains water temperature at setting during thermostat off periods.
Preview Honeywell Heating System AQUASTAT L8124A Installation Instructions Manual Online and Download PDF Manuals & Instructions for FREE from Manualagent.com.
L8124A,C,E,L and M. Aquastat® Relays. APPLICATION. These immersion type controllers are used with forced hydronic heating systems that include domestic hot water service. All models provide high limit, low limit and circulator control. Table 1 lists the various models and their applications. These Aquastat® relays have
High Limit Protection, Low Limit & Circulator Triple Aquastat Relay, High = 10°F, Low Limit = 10-25° Adj Differential. Q: Could you please tell me what is the difference between the L8124A1007 and L8124A1015 triple aquastat controls ? This will be used on a oil hot water boiler. Read More. Asked on 3/14/2011 by AMB
9. Instruction manual. “Tankless coil" boiler application. (Requires a L8124A or C boiler aquastat.) Each zone thermostat will signal the WMCR to start its zone circulator and start the burner. If boiler temperature drops below low limit (circulator) setting, all circulating will cease until temperature of boiler water is increased.
View and Download Honeywell AQUASTAT L8124A installation instructions manual online. AQUASTAT L8124A Heating System pdf manual download.