13. Danfoss Heating Solutions. VIIDH102. 11/2013. User Guide living connect®. 3. ? Room Devices. Bedroom, North. The room contains: Add a device. Remove a device. ^. ^. 0 x. The configuration is invalid: Room has no devices at all. 4. ? Add Room Devices. Keep the device within 1 meter of the controller and get ready.
Danfoss Heating Solutions. Preparation living connect® Z is an electronic radiator thermostat, in- living connect® Z is supplied with adapters for Danfoss. RA valves and valves with M30 x 1.5 (K) connections, two alkaline Press to manually wake up the device. It will stay awake for 10 seconds and send out a node info.
UK. 10 living connect®. 3. Press “Begin Registration", and then press and release on the thermostat. 4. Repeat for each device. 5. Once all devices have been registered and the Danfoss Link™. CC is placed in its final position, perform a network test (see separate Danfoss Link™ CC manual). 3. Installation - step by step
To enter installation mode: Press until M is displayed. Press to withdraw the spindle. M flashes. Reinstall the thermostat on the valve. Press for approx. 3 seconds to fix the thermostat. If the thermostat is moved to another room, make sure to make the necessary changes in the controller. When reinstalling, the thermostat will
DAN_LC-13. Z-Wave Radiator Valve. Thermostat (013). Firmware Version : 3.48. Quick Start. S This device is a Z-Wave Radiator Thermostat. Click on the middle button will confirm inclusion or exclusion and wakeup the device for wireless communication. A long push for 3 seconds on the middle buttons enters and leaves
Hi, in my house I have 8 Danfoss radiator valves LC13 controlled by a virtual thermostat. One of them is getting a bit too hot, so the room temperature is always higher than the others. I would not create a separate thermostat just for this radiator, so I'm trying to set a sort of offset for this valve. In the danfoss manual, I can see
„Wakeup to Configure“. Press the M button again to manually wakeup the Danfoss device for final configuration. Now the device is ready to be used. The Danfoss Thermostat is a battery powered device and will only wakeup after a certain time interval to receive new commands. There is a tradeoff. A more frequent wakeup
Hi guys, today I noticed that two of five Danfoss LC-13 thermostats are greyed out in Habmin after i changed the position of my Cubietruck. Although the two greyed out LC-13 have enough neighbors nothing in log files for these two nodes (7: and 9:) Then I found this manual
The Danfoss living connect is a Thermostatic Radiator Valve (TRV) that can be controlled by a Z-Wave network controller. The battery-powered thermostat is easily fitted to most radiator types in just a few minutes, it can be controlled wirelessly via the Z-Wave network or manually using the unit's three buttons. The thermostat