Zeiss lsm 510 manual: >> http://hss.cloudz.pw/download?file=zeiss+lsm+510+manual << (Download)
Zeiss lsm 510 manual: >> http://hss.cloudz.pw/read?file=zeiss+lsm+510+manual << (Read Online)
Introduction. For your safety! Observe the following instructions: ? The LSM 510 and LSM 510 META laser scanning microscope, including its original accessories and compatible accessories from other manufacturers, may only be used for the purposes and microscopy techniques described in this manual (intended use).
ZEISS LSM 510. CONFOCAL MICROSCOPE. OPERATING INSTRUCTIONS. (Last Revision: 5/21/2009). 1. ZEISS LSM 510 POWER ON/OFF PROCEDURES. POWER ON: 1. Ensure that all of the equipment is turned off. 2. Start the system in the order given: A. the mercury lamp is never switched off; make sure that it is on.
1. Zeiss LSM 510 META user manual. Hege Avsnes Dale, Molecular Imaging Center, UiB. Page 2. 2. Open the LSM software in expert mode. The software opens like this: OBS! Before looking at the sample in the microscope press the VIS button.
Carl Zeiss. LSM 510 META. II. B 45-0008 e 10/02. Knowledge of this manual is required for the operation of the instrument. Would you therefore please make yourself familiar with the contents of this manual and pay special attention to hints concerning the safe operation of the instrument. The specifications are subject to
LSM 510 - ConfoCor 2. The Concept; Measuring Fluorescence Fluctuations. Carl Zeiss. B 40-641 e 05/01. 5. 1. INTRODUCTION. 1.1. The Concept: Measuring Fluorescence Fluctuations. Applications of fluorescence. Fluorescence is a highly specific property of certain dye molecules. Its principles are used in many aspects.
LSM 510. Part I Simple Step-by-Step to Basic Scanning using AxioPlan 2 LSM 510 version 2.8. A. Start-up. 1) Turn-on master switch. 2) Hg Lamp. 3) CTR + ALT + Delete (Note: This is for standard dyes, for custom set-ups please see tutorial on Manually . See Pages 4-23 saving files, 4-39-4-42 of Zeiss Manual
LSM 510 - SETUP REQUIREMENTS. Laser Specifications. LSM 510. 2-10. B 40-051 e 07/98. 2.8. Microscopes. Inverted Axiovert 100 M BP or SP. Upright Axioplan 2 MOT. All Zeiss ICS objectives and accessories can be accommodated. Z motor. DC servomotor, opto-electronically coded. Least Z interval: 100 nm. HRZ-200.
immunohisto-chemistry (single and multiple fluorescent labelling). It is not intended to be definitive users' manual and certainly does not cover all techniques, such as line scans and DIC imaging. Further information and advice can be obtained from the Zeiss manual in the confocal room or from experienced confocal users.
AIM = 'Advanced Imaging Microscopy', acquisition software from Zeiss. Light sources: halogen lamp (for TL), FluoArc mercury lamp (for WFF), lasers (for LSM confocal, or TL in channel D). More information. The Zeiss LSM510 and Axiovert 2000M manual is found on the LSM computers, and in hard copy in the. LSM room.
The objectives, fluorescent filters, condenser, neutral density filters, and field diaphragm on the Axio Observer stand are motorized and can be controlled in the software via the Acquire>Micro submenu or the LCD touchscreen. You may want to find and view your specimen under transmitted light or fluorescence, or both.