5 Dec 2016 3"/5" Concentric Vent System with Intergrated Condensate Collector; Connects to Metal Fab Inc., 3/5" Concentric Venting without an adapter; Next Generation Burner Technology .26 GPM Minimum Flow Rate, .40 GPM Minimum Activation Flow Rate; UMC-117 remote control and 10 ft of thermostat wire is
9 Nov 2009 52 54 60 °C. * Temperatures 85°F(29°C) and up to 140°F (60°C) can be achieved with the Main (UMC-117) remote control . See page. 34 & 35 for minimum and maximum temperature adjustment . Notice: Display shows. °F only. 4. AP15317 (10_09) DV Gas Manual 10 30 09.indd 4. 11/9/2009 3:10:23 PM
Allows you to change temperature settings even while hot water is running. Commercial models allow you set the temperature anywhere between 100? and 180? F, while residential models allow settings between 100? and 120? F. Some models will allow higher settings.
Heat Exchanger Thermistor (Boiling Point Safety). Electronic Burner and Combustion Monitoring and Control. Freeze Protection. Minus 30F (Without Wind-Chill Factor) with power applied. Remote Control. Standard: Main Remote Control UMC-117 (included). Optional: Bath Remote Control USC1-117 – 120 F Max Limit.
The manifold controller (MIC-180) can be installed indoors or outdoors. The main remote control. (UMC-117) must be installed indoors and per instructions provided with the water heater. 2-1. Mounting the Manifold Controller. Make sure the location of the manifold controller allows easy access for service and operation.
temperatures between 100°F (38°C) and. 120°F (49°C). Temperatures of up to 140°F. (60°C) can be achieved with the MAIN. (UMC-117) remote control and a dip switch. adjustment. Only qualified service personnel. should perform this adjustment. Only factory. authorized remote control(s) should be used. In Use Indicator.
To adjust temperature without remote, or higher than 120?F and up to 140?F refer to product manual for dip switch settings. Heavy duty models can be adjusted up to 180?F. Dip switch settings should be adjusted by professionally trained person only. If temperature rise is too much for incoming water temperature, or venting
the MAIN (UMC-117) remote control. Temperatures of 85°F (29°C) can be achieved with the Bath (USC-117 or. USC2-117) remote control. Only qualified service personnel should perform this adjustment. Only factory-authorized remote control(s) should be used. • mended Routine Preventive Maintenance can harm.