ZEISS EVO. Your High Definition SEM with Workflow Automation. Product Information. Version 1.3 400 manual steps to only 15, imaging four points of interest on nine specimens at three different magnifications. . Choose between three chamber size options with EVO MA (10, 15 &. 25). Easily handle samples weighing
The instruments of the EVO family combine high performance scanning electron microscopy with an intuitive, user-friendly experience. EVO can be tailored precisely to your requirements, whether you are in life sciences, material sciences, or routine industrial quality assurance and failure analysis.
Instruction Manual. EVO® series. Scanning Electron Microscope. EVO® Scanning electron microscope. Original instructions. Carl Zeiss Microscopy GmbH. Carl-Zeiss-Promenade EVO® Essential EVO® EVO® EVO® specifications MA 10 and LS 10 MA 15 and LS 15 MA 25 and LS 25 3 nm (2 nm) @ 30 kV . Description
Zeiss EVO MA10. Zeiss EVO MA 10 Features. Filament Type: Tungsten. Detectors: SE/VPSE (environmental)/BSE/EDX. Image Resolution: Secondary Electron = 1.9 nm. Specimen Stage: 5-axis motorized stage A A A A A A A A A 80 x 100 x 35mm (translation XYZ). Tilt angle = a€“ 10 A° to + 90 A°. Rotation = 360 A°
INSTRUCTIONS FOR ZEISS EVO 50VP. SCANNING ELECTRON MICROSCOPE. A. TURNING ON THE INSTRUMENT: 1. Make sure EVO water chiller is on. (Note: this should be left on but check it just to be sure). 2. Open main nitrogen tank valve. DO NOT adjust the pressure regulator. 3. If the EVO is in the STOP position
Features. Thermal emission tungsten firing unit. 200 V to 30 kV accelerating voltage. 5 axis X, Y, Z, rotational, and tilt stage controls. Solid state secondary electron detector and backscattered electron detector. ~100 nm resolution, sample dependent. EVO MA10 SOP_2014
Standard Operating Procedure for Zeiss EVO-50 ESEM (10/18/10). 1. Turn on computer monitors (rightmost button on each). 2. Enter username and password to logon to the NEST lab LAN. 3. Note if there are any conditions in the login screen that are highlighted in red. – these are conditions that should be brought to the
ZEISS EVO. Your High Definition SEM with Workflow Automation. Product Information. Version 1.2 400 manual steps to only 15, imaging four points of interest on nine specimens at three different magnifications. . Choose between three chamber size options with EVO MA (10, 15 &. 25). Easily handle samples weighing
SmartSEM. ®. V05.06. Operating software for Scanning Electron. Microscopes. Software Manual. Carl Zeiss Microscopy - Electron and Ion beam Microscopy Field Mode. FIELD_MODE. 350700-0743. Ability to select field mode (wide field of view) on EVO systems. Fisheye. FISHEYE. 348224-6080. Enables fisheye
Versatile multipurpose SEM. The EVO® MA 10 is the SEM of choice for many users in Materials Analysis. It can be used in both High vacuum & Environmental modes, permitting images of non-conductors. With a large motorised 5 axis stage, variable pressure capability as standard, and easy to use SmartSEM software, the