viii. SEL-487E-3, -4 Relay. Instruction Manual. Date Code 20150626. List of Tables. Table 13.7. First Execution Bit Operation on Automation Settings Change . 13.13. Table 13.8. First Execution Bit Operation on Protection Settings Change, Group Switch, and Source Selection.
The SEL-487B Relay provides bus current differential protection, circuit breaker failure protection, and backup overcurrent buses with no more than seven terminals, use one SEL-487B in a single-relay application. For buses with eight to ten .. The SEL-487B Instruction Manual shows all supported topologies. Figure 23
viii. SEL-487E-3, -4 Relay. Instruction Manual. Date Code 20140522. List of Tables. Table 13.7. First Execution Bit Operation on Automation Settings Change . 13.13. Table 13.8. First Execution Bit Operation on Protection Settings Change, Group Switch, and. Source Selection.
The SEL-551C Relay provides overcurrent relay users with new flexibility in distribution system protection. The SEL-551C provides six inputs and three outputs, with up to two communications ports, for more control options. The SELogic® control equations have added rising and falling edge triggers and latches for custom
SEL-487B. Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection. • Protect busbars with up to 21 terminals using SEL Mirrored Bits® Communications. 87. Current Differential. DFR. Event Reports. HMI. Operator Interface. LGC. Expanded SELogic® Control Equations.
C) 27/59 50 50/BF 51 87 • Dynamic Zone Selection • Monitor Logic for 48 Disconnects Application uses a single SEL-487B Relay with three-phase differential Differential element operation in less than one cycle for internal faults. the relay dynamically selects a higher slope for the Each SEL-487B differential element
7 Oct 2015 The SEL-487B provides optimized bus differential fault detection by using high-speed, subcycle protection coupled with high-security operation for external faults. Superior protection performance is combined with integrated station automation features for seamless transition into new and retrofit
SEL-487B-1 Bus Differential and Breaker Failure Relay and SEL-400 Series Relays. Date Posted: 20171207 Date Code: 20171021. Download. SEL-487B-1 Bus Differential and Breaker Failure Relay. Date Posted: 20171207 Date Code: 20171021. Download. Legacy SEL-487B-0 Relay User's Guide. Date Posted:
The SEL-487B provides optimized, low-impedance bus differential fault detection by using high-speed, subcycle protection coupled with high-security operation for external faults. Superior protection performance is combined with integrated station automation features for seamless transition into new and retrofit applications
3 Aug 2009 Ideally, bus protection provides fast operation (~1 cycle) for any faults that occur within the protection zone. .. The SEL-487B Bus Differential and Breaker Failure Relay is a low-impedance bus differential relay. . Use the SEL-587Z Instruction Manual equation to calculate minimum internal fault operating