MIT515, MIT525, MIT1025, MIT1525. 5, 10 & 15 kV DC Insulation Resistance Testers. DESCRIPTION. The new range of insulation resistance testers (IRTs) are smaller and lighter than previous models yet offer advanced features and rapid charge capability. The range consists of four models; an entry level 5 kV and three
DESCRIPTION. Megger's new range of DC insulation testers MIT515, MIT525,. MIT1025 and MIT1525 are targeted at original equipment manufacturers and industrial companies. The top of the range. MIT1525 performs insulation resistance tests up to 15 kV with a 30 T? maximum resistance and an accuracy of ±5 % from.
MIT515, MIT525, MIT1025 y. MIT1525. Comprobadores de resistencia de aislamiento de 5 kV, 10 kV y 15 kV. MANUAL DEL USUARIO. M En el MIT1525, solo deben utilizarse cables de prueba de Megger clasificados a 15 kV con .. y MIT1525). • Software PowerDB Lite incluido con MIT525, MIT1025 y MIT 1525
Megger MIT1525 Pdf User Manuals. View online or download Megger MIT1525 User Manual.
Safety rated CATIV 1000 V to 3000 m (15 kV) • Rapid charge Li-ion battery • PI, DAR, DD, SV and ramp test • Operate from battery or AC source • Advanced memory with time/date stamp • 30 T? maximum resistance. Megger's range of MIT insulation resistance testers are targeted at original equipment manufacturers and
Page 2. DANGER! Hazardous voltages are • Only 15 kV rated Megger test leads with plug inserts of 75 mm exposed with an AC source connected and the case open. must only be used on the MIT1525. Lead integrity can be.
Only 15 kV rated Megger test leads with plug inserts of 75 mm must only be used on the MIT1525. Lead integrity can be verified by momentarily shorting clips together at the lowest test voltage range. • Circuit terminals must not be touched during an insulation test or before suitable grounding of the unit under test is in place
Megger's range of DC insulation testers MIT515, MIT525, MIT1025 and MIT1525 are targeted at original equipment manufacturers and industrial companies. The top of the range MIT1525 performs insulation resistance tests up to 15 kV with a 30 T? maximum resistance and an accuracy of ±5% to 3 T?. The MIT515 offers IR
Measures up to 30 T? ? PI, DAR, DD, SV and ramp test ? Improved productivity – operate from line power/mains if battery dead ? Li ion battery - extended capacity, rapid charge ? Advanced memory with time/date stamp ? CATIV 600 V safety rating. Offering CAT IV safety, the MIT1525 is compact, light 15 kV insulation
Megger Instruments Limited. MIT1525 15 kV. Industrial Insulation Tester. NEW PRODUCT LAUNCH. SALES GUIDE . The current Megger MIT range of 5 kV and 10 kV range was launched in May 2012 building on a success story of experience and . without the need to refer to the user guide. Always ready to test.