Safety Relays: Type - Safety Relay; Application - E-Stop, Safety Gate , 2-Hand Control, Dual Channel; Input Configuration - 1 NC or 1 NC - 1 NO or 2 NC; Outputs - Safety - 5 NO; Outputs - Auxiliary - 2 NC; Power Supply - 24V AC/DC, 120V AC; Reset - Automatic/Manual, Monitored Manual; Material - Polyester (Case), Red;
Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of
General. The safety relay by itself can not provide safety. The safety relay requires proper component application and maintenance. The application must anticipate failures by using system safety risk assessment. This product must be installed and maintained in accordance with the manufacturer's instructions as.
Relay, Minotaur MSR18T, Safety Monitoring Relay, 24 Volt AC/DC, 120 Volt AC, 3.6 Watt, 20 mA, 4 Normally Closed, 1 Normally Open, Inputs, 5 Normally Open, Safety Outputs, 2 Normally Closed, Auxiliary Outputs, Fixed Terminals, Automatic/Manual, or Monitored/Manual Reset. Available in Select Areas. My Price.
Features. Suitable for applications up to PLe, SIL 3 Per ISO13849-1. Stop Category 0 and Stop Category 1. One or two dual-channel inputs. Two or three safety contacts. One auxiliary contact. Cross-fault monitoring. Rotary switch configures auto/manual or monitored manual reset. Same rotary switch configures AND/OR
Safety Relay,MSR18T,24V AC/DC & 110V AC,Automatic/Manual Monitored,Fixed,90MM,0.5sec,One 2 N.C. Input,One1 N.O and 1 N.C. Input,No Safety Mat Inputs,No LC Inputs,No SAFE EDGE inputs,No SIPHA inputs,5,0,0,0,0,2,0,0,0,0,0,CAT 4 Rated. View More. View Less
Minotaur Safety Relay (MSR) to Guardmaster Safety Relay. (GSR) Conversion – Phase 2. Bulletin 440R. Reference Manual. Original Instructions familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, 440R-ZBR520AZ1 (24V AC/DC and 120V AC).
Safety Outputs Auxiliary Outputs Terminals Reset Type. Power Supply. Cat. No. 1 N.C., 1 N.C. & 1 N.O., 2 N.C. 5 N.O.. 2 N.C.. Fixed. Automatic/Manual or Monitored/Manual 24V AC/DC and 120V AC 440R-ZBR520AZ1. 24V AC/DC and 240V AC 440R-ZBR520AZ2. Copyright © 2014 Rockwell Automation, Inc. All Rights
Cat. No. 1 N.C., 1 N.C. & 1 N.O., 2 N.C. 5 N.O.. 2 N.C.. Fixed. Automatic/Manual or Monitored/Manual 24V AC/DC and 120V AC 440R-ZBR520AZ1. 24V AC/DC and 240V AC 440R-ZBR520AZ2. Approximate Dimensions. Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
Application :Single-fu nction safety relay. Brand Name :Allen-Bradley Guardmaster. Contact Rating : DC-13 2N24V DC. Enclosure :90 mm. Input :1 N.C., 2 N.C., OH NO + 1 NO. Output :5 ND. Power Supply : 24VAC/DC, 120VAC. Standard : CEIcU LusITl'JV. Type : Minotaur Safety Relay. Allen-Bradley 440R-ZBR520AZ1.