JADE Economizer. It's more than just ventilation, it's a solution. Brings in outdoor air to naturally lower a building's interior temperature; Integrates with CO2 sensors to provide demand control ventilation capabilities; Designed to work seamlessly with existing and replacement roof top systems; LCD screen delivers
18 Jul 2017
The JADE™ Economizer System is an expandable economizer control system, which includes a W7220. Economizer Module (controller) with an LCD and keypad. The. W7220 can be configured with optional sensors. The W7220 Economizer Module can be used as a stand- alone economizer module wired directly to a
INSTALLATION INSTRUCTIONS. 62-0331-03. E4436. JADE™ Economizer Module. (MODEL W7220). This document describes wiring, power up, basic troubleshooting, and common installation issues for the. JADE™ Economizer Module (Model W7220). For further information on mounting and operation, refer to
Today, the industry is ready for an economizer that is able to provide more accurate changeover based on dry bulb, enthalpy and dew point. Honeywell developed the JADE economizer to fill this industry need with a microprocessor based digital controller and sensors that input a digital signal for temperature and humidity.
The JADE™ Economizer System is an expandable economizer control system, which includes a W7220. Economizer Module (controller) with an LCD and keypad. The. W7220 can be configured with optional sensors. The W7220 Economizer Module can be used as a stand- alone economizer module wired directly to a
Additionally, the Jade controller must be set to Heat Pump Mode. [System Setup -> Equipment -> HP]. See details on the separate JADE Economizer Module – Product Data. FACTORY-INSTALLED UNITS. The rain hood is not installed at the factory. The hood is packaged and shipped in the space above the unit indoor
When you see this symbol on the unit and in instructions or manuals, be alert to the . Economizer Shroud. 24 mandatory section 120.2 (fault detection and diagnostics) and prescriptive section 140.4 (life-cycle tests, damper leakage, sensor accuracy, etc). If DCV Auto enalbe has been programmed, when the Jade is.
This document is a supplemental installation instruction for the factory-installed. EconoMi$er X (low leak economizer) option. It is to be used with the base unit. Installation Instructions for 48/50TC, 50TCQ, 48/50HC, and 50HCQ 2-Stage cooling units, sizes 08 – 30. Units equipped with the EconoMi$er X option are identified
INSTALLATION INSTRUCTIONS. 62-0331-13. JADE™ Economizer Module. (MODEL W7220). This document describes wiring, power up, basic troubleshooting, and common installation issues for the. JADE™ Economizer Module (Model W7220). For further information on mounting and operation, refer to Honeywell.