This is an addendum to the EDP3-Plus manual (9920-235) which describes pipette operation, modes, and options. Packing List. In addition to this manual, the pipette box should contain: EDP3 instruction manual 9920-235, Rainin Test Report,. Performance Assurance Brochure, sample tips, and labels. Speed Setting.
I run it from fully charge to full drain and it seems to be consistent. Full battery charge seems to take around 2 hours. It can run in a continuous in-use pipette for 2 hours from full charge to drain (which is a decent run time). Overall, it compares hand-in-hand with actual Rainin EDP3 batteries." Price: $72.00. Quantity. Manuals.
In addition to this manual, the pipette box should contain: EDP3-Plus instruction manual 9920-235, Rainin Test Report,. Performance Assurance Brochure, sample tips. Spacing Controls and Indicators. Nozzle spacing is changed with the use of two knurled knobs on either end of the liquid end manifold: the LIMITER knob
Multidispense Mode. Touch any key to switch on. Press the MODE key until. “MULTI" is displayed. “PICKUP" indicates ready for operation. Automatic control: Set aliquot size (e.g. 50 µl) with Up/Down arrows. – EDP3 displays number of aliquots (e.g. 4x). – EDP3 will pick up maximum sample volume. Manual control:.
2 Feb 2007 This reduces tip insertion, ejection and plunger forces. The EDP3-Plus electronic pipette comes with or without an LTS shaft. Already having a set of manual LTS pipettes (which have greatly reduced the stress on my wrists and thumb) it made the most sense for me to have the LTS electronic pipette as well.
Rainin LTS tips must be used with EDP3 multichannel pipettes. E8-10, E8-20, E12-10 and E12-20 use 20µL LTS tips, E8-200 and E12-200 use 250 µL LTS tips. Mounting LTS Tips. Mounting racked LTS tips onto Model E8 and E12 pipettes is simple. First align the shaft nozzles into the row of tips, hold- ing the pipette at a
30 Apr 2010 Simple one-hand operation. EDP3 is easy to use with either hand, even with gloves. The intuitive software allows simple operation without a com- plicated user manual. Plunger forces are completely eliminated, reducing repetitive strain injuries. In models with LTS™, the total pipetting forces are 95% less
Tip Selection. To ensure proper, leak-free fit and conformance to specifica- tions, use only Rainin tips with EDP3 pipettes. When loading tips, press the EDP3 shaft into the end of the tip with only sufficient force to make a positive seal. Tip Immersion Depth. The recommended depth for tip insertion into the sample is shown in
This device (EDP1) is intended for use only as an electronic pipette for pipetting liquids as described in this manual. It is not intended for any other use. Note that pipette specifications and other information in this manual may be changed without prior notice. “EDP1" and “EDP" are trademarks of Rainin Instrument, LLC.
This device (EDP3-Plus) is intended for use only as an electronic pipette for pipetting liquids as described in this manual. It is not intended for any other use. Note that pipette specifications and other information in this manual may be changed without prior notice. EDP, EDP3, EDP3-Plus and LTS are trademarks of Rainin