R8184G4009/U. Protectorelay® Oil Burner Control with 45 second safety timing, alarm outputs, and manual safety switch. Find Equivalent or Replacement Products. Product Info; Literature
Honeywell Protectorelay Oil Burner Control (sku# R8184G4009) with 45 seconds lock out timing provides automatic, nonrecycling control of an intermittent lockout indication available on some models;; Enclosed safety switch with external reset button;; Manual trip lever opens safety switch for system maintenance;
26 Sep 2015 Product Features Include: Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.; Solid state flame sensing circuit.; Enclosed safety switch with external reset button.; Manual trip lever opens safety switch for system maintenance.; Mounts on standard 4 x 4 in.
The Honeywell Protecto Relay provides intermittent ignition oil primary controls to operate the oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat in oil burner systems. Manual trip safety switch lever and lockout indicator light is on the terminal strip which indicates system lockout.
shutdown. [] R8184G model available with manual trip safety switch lever and lockout indicator light on terminal strip. [] 15, 30, or 45 second safety switch timing. D Exposed terminal strip with screw terminals for low voltage connections. D Color-coded leadwires for line voltage connections. D.T. Form Number 68-0113–1.
Honeywell R8184G Manual Online: Typical Hookup With Indicator/isolated Alarm Relay, Troubleshooting. TROUBLESHOOTING AND MAINTENANCE This Control Contains No
A manual reset button is provided to reset the safety switch after lockout. Clock thermostats (not available on R8184P) Check ratings given in the instructions and on the product to make sure the product is suitable for your . R8184G,M,N,P Protectorelay® OIL PRIMARY CONTROLS. Honeywell Limited-Honeywell Limitee.
17 Sep 2013
Find great deals for Honeywell R8184g 4009 Protectorelay Oil Burner Control. Includes - manual trip safety switch and safety lockout indicator light. item 1 Oil Burner Control,No R8184G4009, HONEYWELL CONSUMER PROD GRP -Oil Burner Control,No R8184G4009, HONEYWELL CONSUMER PROD GRP. $92.00.
INSTALLATION. WHEN INSTALLING THIS PRODUCT 1.Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained