Tuesday 20 February 2018 photo 1/5
|
cciss driver reported problems
=========> Download Link http://dlods.ru/49?keyword=cciss-driver-reported-problems&charset=utf-8
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
based on the comment# 3, this bug sounds more like a driver specific issue rather than IA64 Arch problem although the problem is observed on a IPF box... It would be best if we could try on the system that it was originally reported on however it is was moved to the new lab and isn't back up yet. Comment. ... from the cciss driver to the new hpsa: “Some HP Smart Array controllers are now handled by the new 'hpsa' driver, rather than the 'cciss' driver". Welcome hpsa! cciss really sucks!!! Recently there have been problems with a mysql server (Smart Array P410) which reported the following error messages: Debian Bug report logs - #135675 cciss driver problem on debian. version graph. Package: debootstrap; Maintainer for debootstrap is Debian Install System Team ; Source for debootstrap is src:debootstrap (PTS, buildd, popcon). Reported by: Eduard Bloch . Date: Mon, 25. There was a transition to the HPSA driver at some point, moving the Smart Array controller support back into the regular SCSI subsystem versus the dedicated block driver... HP servers from the G1 to G5 era used the CCISS driver. On newer operating systems (EL6 and forward), HP ProLiant G6 and newer. You can try modinfo cciss . On a CentOS 5.x system, I get: [root@XXX ~]# modinfo cciss filename: /lib/modules/2.6.18-164.15.1.el5/kernel/drivers/block/cciss.ko license: GPL version: 3.6.20-RH4 description: Driver for HP Controller SA5xxx SA6xxx version 3.6.20-RH4 author: Hewlett-Packard Company. I am trying to install to disk 1 on the hardware array, I can install to an attached usb stick with no problem except it runs like a thee legged dog (only usb 2.0). So I've. This new driver will support new Smart Array products going forward, and the cciss driver will eventually be deprecated. Initially, there was. scripts and files to create Rockstor iso file. Contribute to rockstor-iso development by creating an account on GitHub. Re: Possible use of driver for HP SmartArray P400(cciss). Postby anderson_thomas » Sat Jul 12, 2014 5:38 am. Hi, I had the same problem. A HP SmartArray P410(cciss) is still working. The y are in HP DL380 G7 for example. Thomas. Top. Any reported issues will require the most current revision of the software (). Driving Licence Centre Johannesburg. How to install CentOS 7 on HP ProLiant. HP ProLiant BL460c G1/G5 is a very stable and reliable. Used under Linux by means of HP Smart Array CCISS driver. Please visit our security site for. Re: Extremely slow io on cciss raid6. hi ulrik, we have the same problem! did you find a solution for now? we have the issue on different HP Servers with different P400 Controllers, everytime the same... my questions: - what hardware revision has your controller? (lspci output) - did you try to put the controller. Go to hp.com and search for your particular server under download drivers & software.. Problems Resolved ----------------- The following issues have been resolved in this release of the HP Array Configuration Utility Command Line Interface. 1.. CCISS interface/driver reports inaccurate information on logical volumes. Hi, We've had a couple of HP servers running 8.10 happily for months. I did an update earlier today and noticed (using hdparm) that the drive speed went from our usual 160-170MB/s (from a 0+1 array over 4x146GB 10k rpm SAS 2.5" drives) to topping out at 35MB/s. This upgrade set the kernel to. Vendor information; 2. Linux kernel drivers. 2.1. Devices nodes note. 3. Management and reporting tools. 3.1. cciss-vol-status; 3.2. hpacucli. According to the manpage it can reports many kind of issues and is much more powerfull than a tools that just tells good or bad; It's looks safe to rely on it as it's. Yes, and even worst - different utilities are reading from different sources (fdisk and sfdisk geometry reports differ in our case.) > Especially c. is a hot candidate for causing you trouble here, you might > try to dig into the details of the partition table content to find out > if it is so. > > You might also try to find. Surface scan analysis is a background process that scans hard drives for bad sectors in fault tolerant logical drives. In RAID 5 or RAID. If you happen to have a HP Smart Array RAID controller that presents this problem, before booting Blancco, remove manually all of the RAID logical array configurations. Recently in several HP machines (HP Proliant DL370 G6 ) with RAID device (I think so due to the /dev/cciss/sdX partitions) ,. Re: HP RAID problem. There is the traditionnal driver for HP Smart Array (cciss that has its devices in /dev/cciss) and a new hpsa driver has been added in 2.6.33 and has normal. For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the nodes which correspond to the RAID controllers. (See note 1.. Additionally failure conditions of disk enclosure fans, power supplies, and temperature are reported as follows: "Fan failed" "Temperature problem" "Door alert" "Power Supply Unit failed". Examples: ./check_cciss -v. RAID OK: Smart Array 6i in Slot 0 array A logicaldrive 1 (67.8 GB, RAID 1+0, OK) (Controller Status: OK Cache Status: OK Battery Status: OK) ./check_cciss -v -p. I am having issues getting an alert in icinga2, are RAID is critical but there is no alert in icinga2. RAID CRITICAL - HP Smart Array. Suspecting hardware issues, I tried it on a 360, same issue. We built these machines before with no problems I used the 8.10 install on our PXE server, and it worked fine. I suspect it's related to the upcoming 8.04.4 release, perhaps a new kernel has been inserted and has missed the cciss driver? Booting using 8.04, and. The Discovery Linux - Disks probe returns information for all IDE and SCSI based disk devices on the server being discovered. A customer reported that disks presented from HP Smart Array Controllers using the CCISS driver were not returning any information from the Discovery Linux - Disks probe. Convince the customer that the incomplete response, ATA output registers missing reports a driver/firmware limitation and not a disk problem. In case of -d sat I would agree. If this happens with -d cciss , then I will not agree. If -d cciss is used, then user explicitly requests CCISS-pass-through protocol. smartctl should never. CVE-2013-2147 > > Dan Carpenter reported issues in the cpqarray driver for Compaq > Smart2 Controllers and the cciss driver for HP Smart Array controllers > allowing users to gain access to sensitive kernel memory. > > CVE-2013-2889 > > Kees Cook discovered missing input sanitization in the HID. For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the nodes which correspond to the RAID controllers. (See note 1, below.) It is not necessary to invoke cciss_vol_status on each logical drive individually, though if you do this, each time it will report the status of ALL logical drives on the controller. For the hpsa. But only half a minute after array start, the H240 declares a fault and aborts, and many of the connected drives are declared offline, which appears to be fatal for this session. unRAID is.. parm: cciss_allow_hpsa:Prevent cciss driver from accessing hardware known to be supported by the hpsa driver (int). #. oi_151 (and probably anything beyond snv_139) cannot be installed or used on some HP Proliant hardware that uses the cpqary3 driver. An attempt to boot the oi_151 install CD results in a kernel panic in cpqary3_retrieve(). This was initially reported as an illumos issue: http://www.illumos.org/issues/348. For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the nodes which correspond to the RAID controllers. (See note 1, below.) It is not necessary to invoke cciss_vol_status on each logical drive individually, though if you do this, each time it will report the status of ALL logical drives on the controller. For the hpsa. I recently run into this issue. The solution is to disable cciss driver by setting MAAS global kernel parameters. MAAS has issues when installing HP machines. This is due to old device driver cciss. This gives naming to block devices which MAAS curtin installer cannot handle. Add this to Global kernel. A driver communicates with the device through the computer bus or communications subsystem to which the hardware connects. When a calling program invokes a routine in the driver, the driver issues commands to the device. Once the device sends data back to the driver, the driver may invoke routines in the original. Updated kernel packages that fix several security issues and several bugs are now available for Red Hat. Michael Tokarev reported a flaw in the Realtek r8169 Ethernet driver in the Linux kernel. This driver allowed. a bug may have caused a system crash when using the cciss driver, due to an uninitialized kernel. I have an old HP Proliant DL360 gen 4 and I would like to install Suse. So I first tried OpenSuse Leap 42.2 but since the server has a Smartarray 6i, which uses CCISS which is no longer supported, the end result is that no hard disks show up. Now, I believe what it is done in these cases is to add a driver by. For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the nodes which correspond to the RAID controllers. (See note 1, below.) It is not necessary to invoke cciss_vol_status on each logical drive individually, though if you do this, each time it will report the status of ALL logical drives on the controller. For the hpsa. Issues Resolved In This Driver Disk. Hotfix XS602E007 updated the XenServer 6.0.2 dom0 kernel version to 2.6.32.12-0.7.1.xs6.0.2.553.170674. This driver is re-issued for compatibility with this new kernel version. The functionality of this driver has not been modified since its first release with XenServer. openSUSE Leap is a free and Linux-based operating system for your PC, Laptop or Server. You can surf the Web, manage your e-mails and photos, do office work, play videos or music and have a lot of fun! Summary, 0000495: Red Hat dropped support for many RAID cards with RHEL7, I'm wanting CCISS support back. ioport:4000(size=256) memory:fddf0000-fddf0fff memory:d0000000-d003ffff(prefetchable) dmesg just says the cciss driver is used. Tags, No tags attached. Reported upstream. Attached Files. HP has been transitioning away from the cciss Linux kernel-driver for a while now, but there hasn't been much information about what it all means. Just on the name alone the module needed a rename (one possible acronym of cciss: Compaq Command Interface for SCSI-3 Support), and it is a driver that. Newer kernel with newer disk and NTFS drivers as usual. Hopefully fixed the problem for the CCISS driver used in a lot of servers, for example the HP DL3xx series and such. Thanks to everyone who reported it, and also to the several people who explanined my mistake (I missed that the access path for it had changed in. I'd guess this has something to do with the cciss driver and dev devices and anaconda not liking that. I don't think raid-install-grub always does the right thing as we have seen with previous bug reports. I think that running it in the post install will cause more problems then it fixes. Comment 10 Charlie Brady. For the cciss driver, the "d0" nodes matching "/dev/cciss/c*d0" are the nodes which correspond to the RAID controllers. (See note 1, below.) It is not necessary to invoke cciss_vol_status on each logical drive individually, though if you do this, each time it will report the status of ALL logical drives on the controller. For the hpsa. ... Comitato operativo per l'emergenza (Operations Commitee of Emergency Situations) Interdisciplinary corporate body in charge of organizational problems.. Forestry Corps) - 1518 CCISS viaggiare informati (Information to drivers) - 1530 Capitanerie di Porto (Harbour office) - Emergency planning Planning activities. Starting with the SUSE Enterprise Linux 11 SP1, the cciss driver supports Px1x Smart Array controllers and prior.... adapter_info - Fix compilation errors in x86_64 and ia64 versions - Fixed segmentation fault in scsi_info.c - Fixed how Emulex model names are displayed in adapter_info - Fixed how QLogic driver versions. boot time, you can add it to /etc/modules.conf as another scsi_hostadapter entry, but you can't duplicate aliases in /etc/modules.conf, so you would use a similar name: Alias scsi_hostadapter_1 cciss After looking at /etc/modules.conf, it looks to see what, if any, running md devices there are, and what RAID level they are. Since I came back to the US last July you can see that one of the big issues I fight with daily is HP servers.. are a different story altogether; the newer servers running CentOS are using an HP controller with SAS drives, using the CCISS (block-layer) driver from the kernel, while one is running Gentoo Linux,. We can see there are a lot of driver requests every day . i suggest two ways to overcome such problems . The driver support.. thank you for the reports, much appreciated! it would be great if you could post the controller models in our wiki. We have lots of HP servers that need cciss (smart array) driver. 5.29 Managing Add-ons from the Command Line Problem You wish to manage available add-ons via the command line using ESXi4. Solution. VMware VMwareCertified ata-pata-via 0.3.3-2vmw.500.0.0.469512 VMware VMwareCertified block-cciss 3.6.14-10vmw.500.0.0.469512 VMware VMwareCertified ehci-ehci-hcd. Q17/ Why does mondoarchive fail saying "No space left on device" although df reports heaps of free space? Q18/ Why does. Q40/ Which drivers does MondoRescue support ? Q41/ How. Q43/ Solutions to "/dev/cciss/c0d0 (or /dev/sda) does not exist" problem with HP Smart Array controllers. Q44/ How to. Hello, is it possible to create vlan interfaces for the 5 networks on two physical network cards? Regards, Peter. #DEVICESCAN -m root -M exec /usr/share/smartmontools/smartd-runner # Alternative setting to ignore temperature and power-on hours reports # in syslog. #DEVICESCAN -I 194 -I 231 -I 9. 2/03 # # Monitor 2 disks connected to the first HP SmartArray controller which # uses the cciss driver. Start long tests on Sunday. To use with older controllers the module parameter is: modprobe hpsa allow_unknown_smart_array=1 Caveats: Controller overlap Issues: /proc/scsi. not well tested possible issues with logical volume expansion during use The driver is based on the cciss code so many things will be familiar to those who. Hi, I try ti install Clearos on HP microserver Gen8 with driver from HP site but not working.. fikse - you might be interested in the information here... http://cciss.sourceforge.net/ detailing the newer "hpsa" driver... checking ClearOS 6.x located the following. It's a little big problem if I put HDD in AHCI mode. 扩展阅读. HP Smart Array CCISS driver - http://cciss.sourceforge.net/. Problem. A quick google brought up this StackOverflow article. CentOS 7 x64 and HP Proliant DL360 G5 SCSI Controller compatibility. Loading the kernel component for the installer (or rather allow HPSA to load any old driver). Altering. On Wed, May 12, 2010 at 4:40 AM, wrote: > Hi all, > > I have an HP server with a P410i RAID controller. I'm using Debian > Sid/Squeeze with the Debian 2.6.32-5-xen-amd64 kernel. If I boot the > kernel without the xen hypervisor (version 3.4 also from Debian) then > I can mount the. Other Drivers. 3. Other Updates; 4. Installation-Related Notes; 5. Update-Related Notes. 5.1. General Notes; 5.2. Update from SUSE Linux Enterprise Server 10 Service. to more easily partition storage already allocated to them from their storage administrators, yet still use dual VIOS and dm-multipath for fault tolerance. I have been running Mincraft server on Ubuntu for ~6 month with no problem.. I really have no experiences rebuiling kernels, so if that is the answer to my problem Please point me to instruction for newbies. Any help would be.. Will's MineOS kernel dose not have the CCISS driver installed so it dose not ASM driver features. 10 system temperature monitoring. 10 system fan monitoring. 10 monitoring the system fault tolerant power supply. 10. ECC memory monitoring and advanced memory protection. 10 automatic... Two are needed during the boot process (the latest cciss driver and the Red Hat Anaconda updates), and. Cciss driver disk for oce. , feature lists of Linux Questi pacchetti non sono internazionalizzati oppure oce sono memorizzati in un formato non analizzabile Per. a free , open internet. prev in list next in list prev in thread next in thread] List: freebsd bugs Subject: Current problem reports From: FreeBSD bugmasterbugmaster. HP ProLiant ML350 G4 Server: Access and download drivers by operating environment, revision, software type, software subtype and language. I have a HP Proliant ML350 that i want to upgrade from Windows server 2003 to Windows server 2008 or 2012, but the problem is that Windows 2008 or 2012 installation cd can't. I found How do I differentiate "fake RAID" from real RAID? - Server Fault. From the HP b140i SmartArray specs: HP Dynamic Smart Array is a RAID solution combining a storage host bus adapter (HBA) and proprietary software components. Eliminating most of the hardware RAID controller components and. I needed to try this update because on my HP ML310e Gen8 v2 servers (i have two), the controller is not initalised at cold boot. The problem is described here. At the time of the writing the latest firmware available for HP P420 FBWC 1GB 2 ports internal SAS controller is 6.0. released in September 2014. In Response To: Problem with tape drive under cciss drivers (Ian Goddard ). Art, mt -f recognises the device and reports that it's a DDS. I don't have the exact response to hand but it seemed sensible enough. The box has 2 smart array devices which use the cciss driver. The other one is battery backed and. 01281332, Upgrade process to Gaia R77.30 on HP platforms that use CCISS driver might end with unresponsive system. Refer to sk106708. 01620955, 01623073, If... 02518182, Memory leak in FWD process, followed by "Segmentation fault" error in /var/log/messages file. 02537839, 02539556, Logging.
Annons