6 • Operating Instructions. Temperature Control Unit P140S/P160S/P180S. Start-up. Setting up the Temperature Control Unit. The temperature control unit is designed for an ambient temperature of. 10-40 °C. Sufficient ventilation must be ensured during set-up. The dis- tance between the devices and/or between the
MASTER OF TEMPERATURE CONTROL. Regloplas-. Temperiertechnik bringt Qualitat und Rentabilitat auf den Punkt! Temperature. Control Technology . 12 One-way check valve. 13 Bypass. 14 Pressure gauge. 15 Manual valve. 16 Consumer. Fig. 7: Principle 90smart; 150 smart. Water. Fig. 11: Principle 90XL. Fig.
Temperature Control Unit Type. 90smart RT33. Temperature range up to 90 °C. Heat transfer medium. Water. NOTE. The technical data and information for installation, start-up and maintenance of the temperature control unit can be found in the maintenance section of these operating instructions. The Operating Instructions
Repair. No display on the controller. The controller has been manually switched offline. No voltage present on the controller. Bring the controller online in accordance with the Operating Instructions. Measure the voltage on the controller. No power to unit. Power system back-up fuse failure. Replace back-up fuse (external).
7 Jan 2018 23 Oct 2017 Download >> Download Regloplas 90 smart manual. Read Online >> Read Online Regloplas 90 smart manual regloplas p140 smart manual regloplas 90 smart password regloplas 90 smart rt 70 regloplas 90s manual regloplas p140s regloplas rt 61 manual regloplas 150 smart
Search Regloplas company's catalogues and technical brochures.
U/q. U/'. U/'. U. U/'. U/'. Electronic flow measurement. ' ' '/q. ' ' ' Manual shut4off valve in the inlet and outlet q. ' U q. ' ' Leak4free pump. U. U. ' U. U. U. Automatic water refill. U. U. U. U/q ; '/q q q. Unit in IP54 protection degree q q. U q q q. Direct cooling q q. U q q q. Equipment. 90smart. 90S. 90XL. 150smart. 150S. 150
heat transfer fluid and increase the pressure drop in the consumer. The Regloplas descaling unit, REG, can be used to descale (>"Regloplas Temperature Control Units" brochure, “REG" Data sheet). The Regloplas Sys- tem Cleaner, SR80, can be used to remove oil deposits (> "Regloplas Temperature Control Units"
90smart. Equipment. RT70 control system, Standard. Solid-state relay (SSR) instead of heating contactor, Standard. immersion pump, Standard. Indirect cooling, Standard. Automatic water refill, Standard. filling tube, Option. Manual shut-off valve in the inlet and outlet, Option. Electronic flow rate measurement, Option.