Friday 5 January 2018 photo 5/14
|
Logical unit not ready manual intervention required emc: >> http://tux.cloudz.pw/download?file=logical+unit+not+ready+manual+intervention+required+emc << (Download)
Logical unit not ready manual intervention required emc: >> http://tux.cloudz.pw/read?file=logical+unit+not+ready+manual+intervention+required+emc << (Read Online)
30 Jan 2010 sd 10:0:0:0: Device not ready: <6>: Current: sense key: Not Ready Add. Sense: Logical unit not ready, manual intervention required. THIS IS NORMAL and expected when using Clariion storage with dm-multipath, according to EMC kb article ID emc187631, "Buffer I/O errors occurring on CLARiiON devices
8 Mar 2011 Mar 9 03:35:05 lme0031 kernel: sd 1:0:3:56: Device not ready: <6>: Current: sense key: Not Ready Mar 9 03:35:05 lme0031 kernel: Add. Sense: Logical unit not ready, manual intervention required. Mar 9 03:35:05 lme0031 kernel: Mar 9 03:35:05 lme0031 kernel: end_request: I/O error, dev sdpw, sector 0
13 Jun 2017 Sep 20 17:42:25 hostname1 kernel: Buffer I/O error on device sda, logical block 0 Sep 20 17:42:25 hostname1 kernel: sd 0:0:0:1: Device not ready: <6>: Current: sense key: Not Ready Sep 20 17:42:25 hostname1 kernel: Add. Sense: Logical unit not ready, manual intervention required
15 Dec 2007 Add. Sense: Logical unit not ready, manual intervention required end_request: I/O error, dev sdb, sector 0 Buffer I/O error on device sdb, logical block 0 sd 1:0:0:0: Device not ready: <6>: Current: sense key: Not Ready Add. Sense: Logical unit not ready, manual intervention required end_request: I/O error
sd 2:0:0:3: Device not ready: <6>: Current: sense key: Not Ready. Add. Sense: Logical unit not ready, manual intervention required. end_request: I/O error, dev sdm, sector 0. unable to read partition table. SCSI device sdn: 52428800 512-byte hdwr sectors (26844 MB). sdn: Write Protect is off. sdn: Mode
30 Apr 2015 kernel: end_request: I/O error, dev sdc, sector 0 kernel: sd 0:0:0:3: Device not ready: <6>: Current: sense key: Not Ready kernel: Add. Sense: Logical unit not ready, manual intervention required. These end_request: I/O error messages are also logged on system console during boot process. On system with
6 Oct 2016 sd 7:0:0:4: [sdf] Device not ready sd 7:0:0:4: [sdf] Result: hostbyte="DID"_OK driverbyte="DRIVER"_SENSE sd 7:0:0:4: [sdf] Sense Key : Not Ready [current] sd 7:0:0:4: [sdf] Add. Sense: Logical unit not ready, manual intervention required. Nov 4 14:38:23 netezza01 kernel: INFO: task lvm:21212 blocked for
22 Jun 2009 Hi We are migrating from a NetWare cluster against an EMC CX500 SAN to a new OES2SP1 LX cluster running against a CX4-120. The OES2SP1 LX cluster was Jun 22 18:36:00 sblx-1 kernel: Additional sense: Logical unit not ready, manual intervention required. Jun 22 18:36:00 sblx-1 kernel:
12 May 2009 Pseudo name="emcpowern". Symmetrix ID="xxxxxxxxxxxxxx". Logical device ID="0770" state="alive;" policy="SymmOpt;" May 9 16:50:03 adeld194p kernel: Add. Sense: Logical unit not ready, manual intervention required. May 9 16:50:03 adeld194p kernel: May 9 16:50:03 adeld194p kernel: end_request: I/O
4 Aug 2010 end_request: I/O error, dev sdc, sector 52428792. Buffer I/O error on device sdc, logical block 6553599 sd 0:0:0:2: Device not ready: <6>: Current: sense key: Not Ready Add. Sense: Logical unit not ready, manual intervention required. end_request: I/O error, dev sdc, sector 0. Buffer I/O error on device sdc,
Annons