Tuesday 20 March 2018 photo 7/15
|
Acm12 installation manual: >> http://ocu.cloudz.pw/download?file=acm12+installation+manual << (Download)
Acm12 installation manual: >> http://ocu.cloudz.pw/read?file=acm12+installation+manual << (Read Online)
ACM12. Installation Manual V4.5 and higher. Supports EVOHD / EVO192 V4.5 and higher. Description. Thank you for choosing the ACM12 for your access control. The ACM12 is designed to be used with the Paradox EVO system. It allows you to manage access of one door, via card, pin or both, provide forced door and
Jan 30, 2017
Installation Instructions paradox.com. Printed in Canada 05/2014. ACM12-EI02. Introduction. The Access Control Module (ACM12) is designed to be used with the Digiplex EVO. System control panels. Each ACM12 allows you to connect a reader, a REX device, a door contact and a locking device to control the access to
Instructions d'installation paradox.com. Imprime au Canada 11/2007. ACM12-FI01. Introduction. Le Module de controle d'acces (DGP-ACM12) est concu pour fonctionner avec les panneaux de controle des systemes Digiplex EVO. Chaque DGP-. ACM12 permet a l'utilisateur de se connecter a un lecteur, un dispositif REX,.
Installation Instructions paradox.com. Printed in Canada 05/2014. ACM12-EI02. Introduction. The Access Control Module (ACM12) is designed to be used with the Digiplex EVO. System control panels. Each ACM12 allows you to connect a reader, a REX device, a door contact and a locking device to control the access to
Mar 14, 2011
The Paradox ACM12 4-Wire Access Control Module is designed to be used with the Digiplex EVO System control panels. Each ACM12 allows you to connect a reader, a REX device, a door contact and a locking device to control the access to one door. If desired, door contacts can also be assigned to zones in the control
The Paradox ACM12 is a single-door access control panel designed to be used with Paradox EVO panels including the EVO192 (V4.5 and higher) and the new EVOHD (V4.5 and higher). It allows the user to manage 1 door via card, PIN, or both card and PIN. It supports both an IN and OUT reader if using 4-wire Paradox
PGM ACM12 Installation Instructions Cathode Connection Diagrams 1N4007 Diode Anode ** Door contact must be connected to CT terminal * = Follows control panel's EOL definition. ** = If the door contact is not used, install a jumper or a 1k resistor across the AUX- and CT terminals depending on the control panel's
ERROR (Red):Indicates a problem with the module. RX (Green): Flashes when receiving information from the panel. TX (Green): Flashes when transmitting information to the panel. To PGM output DGP-ACM12 Installation Instructions paradox.com Printed in Canada 09/2007 Introduction External Negative Trigger Error RX
Annons