Sensitive, Accurate, Rugged, and Reliable, these words describe a TA Instruments rheometer. Our exciting new rheometers are fifth generation products from the pioneer of controlled stress rheology. Designed with the customer in mind, and backed by the superior customer support, which is the hallmark of TA Instruments
AR2000 Rheometer: Instructions. Please see Danielle for training before your first use. Instrument Setup. Note: The order in which the things are powered on is very important! 1. Connect Make sure the compressed air line is open before turning on the instrument. This may When re-filling with water add 3-4 drops of TA.
communication is not established, the page will appear blank. The Instrument. Status Page can also be used to manually control the instrument. 8. Instrument Inertia (See Smart Swap operational instructions by going to Start>Programs>TA Rheology Advantage>Rheology Advantage Manuals: AR2000 pg 5-6). 2 of 7
The most common temperature control option for the AR Series rheometers is the Peltier Plate. Over 20 years ago, TA Instruments was the first rheometer supplier to introduce Peltier Plate temperature control. TA Instruments understands the value of Peltier heating and cooling for rheological measurements and has
The AR Series rheometers offer unmatched performance and ease-of-use due to unique and superior design. These technologies are optimized and integrated into rheometer systems that deliver the best fundamental rheology meas- urements. Continuous innovations drive each generation of the AR Series for better
Device specifications. The durable porous carbon bearing of the AR2000ex results in low residual torques which allows outstanding torque control from 0.0003. µN.m up to 200 mN.m with a resolution of 0.1nN.m. The advanced ultra-low inertia drag cup motor further reduces system friction and delivers a faster transient.
2008 TA Instruments. AR Rheometer. Instrumentation, Calibration. & Maintenance Primary Things. Power up. Main Power. Switch. Instrument Power. RS232 Debug. RS232 Computer. RS232 Aux. Exp. Signal swap base of the AR2000 and. AR-G2. An upper heated compensation heater [UHP]is available to eliminate
A rheometer, therefore, measures material behavior such as yield stress, complex viscosity, modulus, creep, and recovery. Instrument components. The AR 2000ex rheometer used in this laboratory contains an electronically-controlled induction motor with an air bearing support for all the rotating parts. The air bearing is
The material contained in this manual is believed adequate for the intended use of this instrument. If the instrument or procedures are used for purposes other than those specified herein, confirmation of their suitability must be obtained from TA Instruments. Otherwise, TA. Instruments does not guarantee any results and.
The material contained in this manual, and in the online help for the software used to support this instru- ment, is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes other than those specified herein, confirmation of their suitability must be obtained from TA.