Friday 9 March 2018 photo 12/15
|
Fluke 80k-40 instructions: >> http://oro.cloudz.pw/download?file=fluke+80k-40+instructions << (Download)
Fluke 80k-40 instructions: >> http://oro.cloudz.pw/read?file=fluke+80k-40+instructions << (Read Online)
measuring high voltage with multimeter
fluke 80k-40 price
fluke 80k-15
high voltage meter multimeter
how to use high voltage probe
fluke 80k-40 specs
what is a high voltage probe
fluke 80k-6
Instruction Sheet. Introduction. The 80K-15 Electronic Air Cleaner Probe (hereafter referred to as “the probe") is a low energy probe that extends the voltage measuring capability of an ac/dc voltmeter or multimeter. Properly connected, the probe is rated to 15 kV Overvoltage. Category I. The use of the probe is restricted to
Full text of "FLUKE 80K 40 Instruction". See other formats. Maintenance Performance Test Verify the probe accuracy by measuring a 25 kV dc ±0.25% voltage source. When used with a compatible dc voltmeter, the probe should measure the source with ±1% accuracy. No calibration adjustments are provided. Cleaning Use
Overview: Features: Models: Accessories: Resources. The 80K-40 is a high voltage probe designed to extend the voltage measuring capability of an AC/DC voltmeter to 40,000 volts peak AC or DC Overvoltage Category I. This means the probe can only be used to make measurements on energy limited circuits within
The 80K-40 is a high voltage probe designed to extend the voltage measuring capability of an AC/DC voltmeter to 40000V peak AC or DC overvoltage category I. This means the probe can only be used to make measurements on energy limited circuits within equipment. Examples include high voltage within televisions or
Never use solvents or abrasive cleaners. Make sure the 80K-40 is dry before reuse. FLUKE. 80K-40. High Voltage Probe. Instruction Sheet. Introduction. The Model 80K-40 is a high voltage accessory probe designed to extend the voltage measuring capability of an ac/dc voltmeter up to 40,000 volts Overvoltage Category 1.
May 19, 2016 I've used their Voltage Dividers for a long time. They're really good. You can call Ross Engineering if you want. If anybody can help, it's these guys. www.rossengineeringcorp.com/contacts.html. 80K-40's are ±1% DC and 5% AC. See note in UUT Instruction Sheet (PN 481978):. * The input impedance
Mar 22, 2012
Buy Fluke 80K-40 High Voltage Probe: Test Probes & Leads - Amazon.com ? FREE DELIVERY possible on eligible purchases.
Fluke Europe B.V.. P.O. Box 9090. P.O. Box 1186. Everett, WA 98206-9090. 5602 BD Eindhoven. U.S.A.. The Netherlands. 5/94. ®. 80K-6. High Voltage Probe. Instruction Sheet. Description. The 80K-6 is a high voltage probe designed to extend the voltage measuring capability of an ac/dc voltmeter to 6000 volts peak AC.
Fluke 80K-40 Thermometer User Manual. Page 1. Page 2. Page 1. Open as PDF. of 2. Maintenance. Performance Test. Verify the probe accuracy by measuring a 25 kV dc ±0.25%. voltage source. When used with a compatible dc voltmeter, the. probe should measure the source with ±1% accuracy. No. calibration
Annons