ul 2079
10 Dec 2008 FOR COMMITTEE USE ONLY, NOT FOR SALE OR DISTRIBUTION. UL Standard for Safety for Fire Tests of Through-Penetration Firestops, UL 1479. Third Edition, Dated May 23, 2003. Summary of Topics. These revisions to ANSI/UL 1479 are being issued to correct the revisions issued on February.
Table of Contents. Introduction. 4. Introduction to Fire Protection. 5. Terms and Definitions. 8. Fundamentals in Firestopping. 15. Test Standards Associated with Firestop. 23. - ASTM E 814 / UL 1479 (through-penetrations). 24. - ASTM E 84 / UL 723 / NFPA 255 (surface burn). 27. - UL 2079 (joints). 28. - ASTM E 2307 (curtain
UL 1479. Fire Tests of Through-Penetration Firestops. UL 2079. Tests for Fire Resistance of Building Joint Systems. In Canada: ULC S115-M05. Standard Method of Fire Tests of Firestop Systems. TESTED BY THIRD PARTY AGENCIES. Underwriters Laboratories, Inc. (UL). Intertek Testing Services Inc. – Warnock Hersey
27 Apr 2007 UL 1479 “Fire Tests of Through-Penetration Firestops" has been revised to incorporate a change to the way that samples are constructed to test certain F-A and F-C series of firestop systems. The F-A and F-. C series of systems cover penetrations through concrete floor/ceiling assemblies and wood framed.
20 Sep 2007 UL 1479 “Fire Tests of Through-Penetration Firestops" has been revised to incorporate a change to the way that samples are constructed to test certain F-A and F-C series of firestop systems. The F-A and F-. C series of systems cover penetrations through concrete floor/ceiling assemblies and wood framed.
1. 209625. Flexible firestop sealant CP 606. Technical data. Chemical basis. Water-based acrylic dispersion. Base materials. Concrete, Masonry, Drywall, Steel. Tested in accordance with. UL 2079, ASTM E814, ASTM E1966,. UL 1479, CAN/ULC-S115. Movement1). ±12.5% (ISO 11600). LEED VOC. 75 g/l. Can be painted.
Through penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E 814 or. UL 1479 with a minimum positive pressure differential of 0.01 inch (2.49. Pa) of water and shall have an F rating of not less than the required fire resistance rating of the wall penetrated.
to ASTM E814 or UL 1479 by accredited testing agencies. These systems should be published and readily available via the internet or other means. Verify that the Through-Penetration System being used has been tested to the hourly rating necessary (ie. 1 hr., 2 hr., etc,) based on the type of assembly being penetrated.
2 Aug 2013 Directory. Look for the UL Classification Mark on the product. 3M Fire Barrier Rated Foam, FIP 1-Step for use in Through-Penetration Firestop System Nos. C-AJ-0140, C-AJ-1628, C-AJ-1629, C-AJ-3321, C-AJ-4098, C-AJ-5347, C-AJ-8217, W-J-1231,. W-J-1232, W-J-4073, W-L-1478, W-L-1479, W-L-4082.
ul 1479 - national fire protection association - nfpa - for committee use only, not for sale or distribution ul standard for safety for fire tests of through-penetration firestops, ul 1479 third edition, dated may 23, 2003ul 1479 pdf pdf download - pressedflowerpatch - ul 1479 pdf ul 1479 national fire protection association nfpaorg,