Document number: 1SDH000460R0002 Content: rs Installation and service instructions 1SDH000460R0002 L6555 L6555 Emax ABB SACE Doc. no. Manual. 2011-06-16. Current sensor E1-E2-E3 3p -4p. German, English, Spanish, French, Italian - 1,77MB. Content: adCenter/ - Proceed with the installation of the
The series of SACE Emax circuit-breakers consists of five sizes (E1, E2, E3, E4, E6) versions fixed and withdrawable, with rated uninterrupted currents from 800 to 6300 A and breaking capacities up to 150kA at 440Vac, 100kA at 690Vac and 65kA at 1000Vac. For each size there are multiple models with different breaking
Emax. ABB SACE. Doc. no. Model. Apparatus. Dwg. Title. App. Resp. Off. Take over Off. Scale. Language. EN. 1SDH000460R0002. Installation, service and maintenance instructions for low voltage air circuit-breakers. • READ THIS DOCUMENT AND THE INSTRUCTION MANUAL CAREFULLY BEFORE ATTEMPTING TO.
L0849. Emax. ABB SACE. RH0287002. Installation, service and maintenance instructions for the fixed part of withdrawable version circuit-breakers. Doc. N° .. Note. The table regards fixed parts with horizontal rear terminals. Fixed part. Withdrawable 3 poles Withdrawable 4 poles kg kg. E1. 25. 28. E2. 28. 32. E3. 38. 45.
L2234. L4681. L5179. Emax. ABB SACE. L2778. Doc. no. Model. Apparatus. Dwg. Title. App. Resp. Off. Take over Off. Scale. Language. EN. 1SDH000460R0002. Installation, service and maintenance instructions for low voltage air circuit-breakers. L5439
The SACE Emax family of air circuit-breakers consists of six sizes: X1, E1, E2, E3, E4, E6 up to 6300A. .. Optional Module PR120/D -M COM, PR120/K , PR120/D -BT for ABB SACE PR122/P e PR123/P unit (German, English, Spanish, French, Italian - pdf - Manual) · Padlock for safety shutters (German, English, Spanish,
15 Mar 2005 The new Emax range shines like a light from within: the new generation of trip units is fitted with the latest advances . E3. E4. E6. 404 / 530. 566/656. 746 (2). 782/908. 1034 (2). 15.91 / 20.82. 22.28/25.83. 29.37. 30.79/35.78. 40.71. 432 / 558. 594/684. 774 (2). 810/936 .. Pushbutton for manual opening. 4.
23 Mar 2014
New Emax. Lively performances. Emax E1 now offers current ratings up to 1600A, whilst. Emax E3 is enhanced by version V with top of the range performances. Always aware of the rapid changes in the market, ABB SACE has made some specific versions to cover new applications and simplify retrofitting operations.
ABB SACE. Emax UL Listed. Installation and service instructions. 1SDH000533R0002 L5838. Installation, service and maintenance instructions for the fixed part Emax UL. 6/34. Doc. N°. Model. Apparatus. Scale. Page N°. 1SDH000533R0002. L5348. L5639. L5838. Fig. 9. Fig. 8. E1 - E2 - E3. E4 - E6. 4.3 Installation of