Oxford Instruments Energy-Dispersive Spectroscopy (EDS). Operating Manual. This document is intended to describe the operation of the Oxford EDS system and its capabilities. In order to gain access on the tool, a formal qualification by staff is required. FIB Scios and the EDS system have two separate qualifications,
Step 1: Enter Project Notes and Specimen Notes for the sample in “Describe Specimen". Step 2: Select “Ratemeter" in the “Mini View" to verify the dead time and input count rate. Step 3: Perform a “Beam Measurement" in “Optimize" Calibrate step (If interested in un-normalized quant). Step 4: Collect a reference image in
AZtecEnergy EDS Microanalysis software enables high speed acquisition, analysis and reporting - what used to take minutes now takes seconds. The user interface that can be quickly adapted to the need of different users in a large department, while real-time mapping automatically corrects for overlaps, pile-ups,
21 Jul 2011 Original Instructions. ABOUT THIS GUIDE. This guide provides basic information for using the Oxford Instruments NanoAnalysis (OINA). MicroAnalysis System for Scanning Electron Microscopes (SEM) and Transmission Electron. Microscopes (TEM) in Energy Dispersive Spectroscopy (EDS) applications.
Oxford EDS Instruction Manual. Digital Imaging and Spectra Collecting with INCA. In emergency, please contact: Dr. Haitao Zhang, 7-8128 (Office), 704-582-3323 (cell), hzhang3@uncc.edu. 1. In SEM system: (a) Select the desired Accelerating Voltage: for EDS, the recommended accelerating voltage is 1.5 to 2 times the
If a PC where you installed the software products does not have access to the inter- net, you need a unique unlock code from the internet-based licensing service to enable you to use the software product. This long code needed to be manually cop- ied and taken to a PC with internet access, where it had to be manually
We provide a choice of systems from routine EDS microanalysis on a budget, through integrated solutions for specific applications, to advanced nanoanalysis where performance counts.
INCA Energy Operator Manual. INCA Energy. Operator Manual. Issue 2.1. January 2006. Oxford Instruments Analytical. Halifax Road. High Wycombe HP12 3SE, UK EDS detector to detect X-rays. The PC is loaded with the INCA . Select INCA Viewer from Start/Programs/Oxford Instruments menu. Copying spectra
The x-ray data acquisition is done by Oxford spectrometer attached to the SEM chamber, and the spectrometer is control by the Oxford INCA software. Procedure. I. Setting up the microscope and INCA (EDS acquisition program). 1. Sign in to the session via the computer in the hallway. 2. At the login screen select 'Quanta