VELA® ventilator. Comprehensive. Versatile. Proven. Healthcare providers need solutions that empower them to deliver quality patient care. The VELA® ventilator 40,000-hour warranty on the turbine. • Accurate, integrated FiO2 delivery, monitoring and alarms. • Complete 24-hour trended data of all patient parameters.
Consult CareFusion 's VELA® ventilator brochure on MedicalExpo. Page: 1/4.
VELA® ventilator. Comprehensive specifications. Primary settings. Rate. 2 to 80 bpm. Tidal volume. 50 mL to 2.0 L. Inspiratory pressure. 1 to 100 cmH2O. Peak flow. 10 to 140 L/min,. (180 L/min spontaneous maximum). Inspiratory pause. OFF, 0.1 to 2.0 seconds. Inspiratory time. 0.3 sec to 10.0 seconds. Pressure support
ventilator software screens. Some of the functions accessible from this screen are for use by a trained technician when servicing the VELA ventilator.*. Extended Functions (continued). Events. Stores data events for service evaluation and troubleshooting*. Transducer test. Allows service testing of transducer function*.
Operator's manual. Vela Ventilator Diamond Series iv. L3264 Rev. M. Added a warning that states that an oxygen monitor should be used while using the low flow option. In the section “Items Required for Ventilation Setup," removed the phrase that states that medical grade oxygen flow rate is not to exceed 80 L/min at 0.5
THE VELA ventilator systems are warranted to be free from defects in material and workmanship and to meet the published specifications for two (2) years or 8,000 hours, whichever occurs first. The turbine only is warranted to be free from defects in material or workmanship for five (5) years or 40,000 hours whichever
Service Manual. 3. Warranty. THE Vela ventilator systems are warranted to be free from defects in material and workmanship and to meet the published specifications for two (2) years or 8,000 hours, whichever occurs first. The turbine only is warranted to be free from defects in material or workmanship for five (5) years or
THE AVEA® ventilator systems are warranted to be free from defects in material and workmanship and to meet the published specifications for Two (2) years or 16,000 hours, whichever occurs first. The liability of VIASYS Respiratory Care Inc. (referred to as the Company) under this warranty is limited to replacing, repairing
22 Apr 2013 BChapter 8: Troubleshooting/Codes 52 Service Manual VELA Ventilator SystemsL2859-101 Rev. BDelivered Volumes Test TroubleshootingProblem Possible Cause VELA Ventilator Systems Service Manual 53L2859-101 Rev. BFiO2 Performance Test TroubleshootingProblem Possible Cause 54 Service
Vela User's Guide L1536 Rev. C. New Patient Set-Up. 1. Power on the ventilator and perform operational verification testing as described in Chapter 2 of your Operator's Manual. 2. Select "NEW PATIENT". Touch "PATIENT ACCEPT". 3. Select Active or Passive Humidification. 4. Enter patient ID if desired. 5. Select “LEAK