danfoss pressure switch wiring diagram
The RT single pressure switches series consist of a variety of ordinary controls including neutral zone pressure switches, safety pressure switches for steam boiler plant, and gold plated fail-safe controls for applications in which safety or economical consequences are critical factors. RT switches have been in service for
The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems. They can also be used to start / stop compressors and fans for air-cooled condensers. They are available in both single and dual versions.
Type. Regulation range. PS/MWP. KP 1. -0.2 – 7.5 bar. 17 bar / 245 psig. KP 1 reset. -0.9 – 7 bar. 17 bar / 245 psig. KP 5. 8 – 32 bar. 35 bar / 510 psig. KP 5 reset. 8 – 32 bar. 35 bar / 510 psig. Enclosure. A: M4 (8 – 32 UNC). C: Enclosure IP44. (EN 60529). B: Enclosure IP30. (EN 60529) ptest max. KP 1, KP 1A: 20 bar pe
The KP Pressure switches are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. They are also used for starting and stopping refrigeration compressors and fans on air-cooled condensers. The KP Pressure switches are
A KP pressure switch can be connected directly to a single-phase AC motor of up to approx. 2 kW or installed in the control circuit of DC motors and large AC motors. KP pressure switches are fitted with a single-pole double-throw (SPDT) switch. The position of the switch is determined by the pressure switch setting and the
KP pressure controls are for gaseous media and air. KPI pressure controls are suitable for plant in connection with liquid and gaseous media. Introduction. The pressure controls are fitted with a single- pole switch changeover (SPDT). The position of the switch depends on the setting of the pressure control and the pressure
For complete list of approved refrigerants, go to products.danfoss.com/all-products/. Connections. Connections for KP 1A, KP 5A, KP 6AS. Mounting. -40 – 65 °C. -25 – 65 °C (PED approved units). Relative humidity RH: 30 – 98%. Vibrations resistance: 4 g (10 – 1000 Hz). PS/MWP. (Maximum Working Pressure). Type.
CAUTION: Disconnect power supply before wiring connections are made or service to avoid possible electrical shock or damage to equipment. Do never touch live parts with your fingers or with any tool. Wiring. All wiring should conform to the National Electrical Code and local regulations. Terminal block. CAUTION:.
discharge pressure. KP pressure controls are also used for starting and stopping refrigeration compressors and fans on air-cooled condensers. KP pressure controls are fitted with a single-pole double-throw (SPDT) switch. The position of the switch is determined by the pressure control setting and the pressure at the
DKRCC.PD.CD0.A2.02 / 520H5628. Technical brochure. Pressure controls,. Type KP. Features. • Ultra-short bounce times. • Reduces wear to a minimum and increases reliability of the switch is determined by the pressure control setting and the .. the pressure in KP1 has raised 0.7 bar above set value and in KP6 and