and operation of CADD® pump infusion systems. The issue date of this Technical Manual is included for the user's information. In the event one year has elapsed between the issue date and product use, the user should contact Smiths Medical to see if a later revision of this manual is available. Issue Date: November 2010
The air detector has detected air in the fluid path; the fluid path may contain air bubbles. Acknowledge the alarm. Then, if the fluid path contains air bubbles, close the clamps, disconnect the fluid path from the patient, and follow the instructions for priming to remove the air. Battery depleted. Pump stopped. Alarm Priority High
This booklet provides guidelines for the use, care and maintenance of the CADD-Prizm® VIP Ambulatory Infusion Pump. The Operator's Manual provided with this product contains warnings and cautions that the user should be aware of for the safe use of the product. If you have any questions regarding these systems,
PCA pump. Model 6300 - 100ml Cassette. HOW TO START THE CADD PUMP. Press and hold the stop/start button. Three dashes will count down under the . THAT THE TUBING COMING OUT OF THE PUMP IS INSERTED INTO. THE AIR DETECTOR. SEE PAGE 35 OF THE OPERATORS MANUAL. START PUMP.
This manual concerns only the Deltec CADD-Prizm® PCS II (Pain Control. System) Model 6101 ambulatory infusion pump. This pump can be pro- grammed to deliver medication at a constant rate and/or to allow delivery of a bolus dose at a specified time interval. This manual is intended for clinician use only. Do not permit
1 Jun 2005 This manual concerns only the CADD-Prizm® PCS (Pain Control System). Model 6100 and 6101 ambulatory infusion pumps. This pump can be pro- grammed to deliver medication at a constant rate and/or allow delivery of a bolus dose at a specified time interval. This manual is intended for clinician use.
should contact Smiths Medical MD, Inc. to see if an updated revision of this manual is available. Technical Assistance. If you have comments or questions concerning the operation of the CADD®-Solis ambulatory infusion pump, please call the number given below. When calling, please specify the pump's software version.
There are a few variations of the CADD pump used by ambulatory patients. Get a good review While there is an actual CADD pump key, unless your patient has been given a pump with an elevated lock level, you have no need for it. The various . The link for the CADD Legacy Pump User manual for CLINICIANS ONLY.
12. If a cassette is attached, latched and locked (if using the PCA therapy), the “Prime tubing?" screen may appear. The “Start pump?" screen appears. Select Yes to start the pump immediately or No to start the pump at a later time. Manual Mode Programming. You can manually program the CADD®-Solis VIP pump if the
Technical Assistance. For detailed instructions, specifications, warnings, warranties, and additional information on operating the CADD®-Solis VIP ambulatory infusion pump, refer to the Operator's Manual supplied with the product. Smiths Medical is available to help with the programming and operation of the CADD®-Solis