IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This manual contains important safety instructions that should be followed during the installation and maintenance of the Liebert DS™. Read this manual thoroughly before attempting to install or operate this unit. Only qualified personnel should move,
this manual to see if the issue can be resolved by following outlined procedures. For additional This section describes the model-number configuration for Liebert DS units and components. 1.1 Liebert DS Description. 1. Air-cooled—Unit piping is spun closed from the factory and contains a nitrogen holding charge.
The basic temperature cooling control band is established at the temperature set point with the length equal to ? of the programmed temperature proportional band divided by the number of cooling stages. The Liebert DS units are supplied with two (2) compressors, each compressor is rated at ? of the unit capacity.
Precision Cooling. For Business-Critical Continuity™. Liebert® DS™. System Design Manual - 28-105kW (8-30 Tons), Downflow/Upflow, 60Hz. Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL, Dual-Cool
TABLE OF CONTENTS. 1 Important Safety Instructions. 7. 2 Nomenclature and Components. 15. 2.1 Liebert DS Model-number Nomenclature. 15. 2.2 Component Location. 17. 3 Pre-installation Preparation and Guidelines. 19. 3.1 Planning Dimensions. 19. 3.2 Air-distribution Considerations for Downflow Units. 20.
We offer a variety of CRAC and Environmental Units from top brands, including Liebert, Stulz, APC, Airflow, Compuaire & more, call 208-667-5441 today! Understand some of these manuals are 20+ years old and are the only copies available on the internet. Having Description, Make, Download. DS - Parts Manual
Figure 1 Downflow model component locations · Figure 2 Upflow model component locations · Figure 3 Liebert DS model number nomenclature · 2.0 Cooling Configurations · 3.0 Pre-Installation Guidelines · 3.1 Room Preparation · 3.2 Air Distribution-Downflow Units · Figure 4 Downflow unit ducting and plenum ducting.
PRECISION COOLING. LIEBERT DS™. TECHNICAL DATA SUPPLEMENT. 28-105kW. 8-30 Tons. Downflow. 60Hz PIPING CONNECTION SIZES - Air-Cooled Liebert DS Unit. Liquid Line - O.D. Copper (2/unit). 1/2. 1/2. 1/2. 5/8. 5/8. 5/8 The manual disconnect switch shall be mounted in the high voltage section of
With the electric power to the unit OFF check the following items as noted: Internal piping clamps tight and secure on Evaporator and Condenser. Field piping properly supported and secure. Hot Gas line pitched according to User Manual. Field piping trapped according to User Manual. Field piping properly sized according
Manuals · Brands · Emerson Manuals · Control Units; Liebert DS. Emerson Liebert DS Manuals. Manuals and User Guides for Emerson Liebert DS. We have 1 Emerson Liebert DS manual available for free PDF download: User Manual. Emerson Liebert DS User Manual (100 pages). Intelligent Communications &