Danfoss kp5 manual: >> http://qbh.cloudz.pw/download?file=danfoss+kp5+manual << (Download)
Danfoss kp5 manual: >> http://qbh.cloudz.pw/read?file=danfoss+kp5+manual << (Read Online)
danfoss pressure switch kp35 manual
danfoss dual pressure switch kp 15
danfoss pressure switch wiring diagram
danfoss dual pressure switch wiring diagram
danfoss pressure switch kp1
danfoss hp lp switch wiring
danfoss pressure switch adjustment
danfoss kp 15 wiring diagram
Looking for a Danfoss 060-117366 Pressure Switch? You can order online today at great prices and collect in your local branch of have it delivered to where you need it | Climate Center.
Manual reset. Type. Differential. KP 1, KP 1A. 0.7 bar (10 psi). KP 5, KP 5A. 3 bar (43 psi). KP 6B, KP 6S, KP 6AB,. KP 6AS, KP 7B, KP 7S. 4 bar (58 psi). CAUTION: Disconnect power supply before wiring connections are made or service to avoid possible electrical shock or damage to equipment. Do never touch live parts
use FINGERS ONLY! (Do NOT use screwdriver). To resume control operation after safety cut-out, push man. reset knob as indicated. Note: LP man. reset is possible only after system pressure has risen above cut-in value. HP man. reset is possible only after system pressure has dropped below cut-out value. Manual reset.
Drawing, KP 1, 2, 5, 7 pressure control, solder conn. 150x68px (0 KB gif) 300x139px (7 KB jpg). Drawing, KP 1, KP 2, KP 5, KP 7W, Auto reset (US version), 267x143px (1 KB gif) 533x289px (17 KB jpg). Drawing, KP 1, KP 2, KP 5, KP 7W, Auto reset (US version), 227x200px (16 KB jpg) 227x200px (16 KB jpg) 227x200px
19 Feb 2014
entry can also be used for 6 - 14 mm cable. manual reset, the top cover must be separately. With 8 — 16 mm cable a standard Pg 16 screwed ordered (code no. 060-109766 for single cable entry can be used. pressure switches and code no. 060-109866 for dual pressure switches). Enclosure. IP30 to EN 60529 / IEC 60529
Danfoss A/S (AC-MCI / jmn), 2014-02. Contact 1-4 opens on pressure drop. KP 1, KP 1A. Contact 1-2 opens on pressure rise. KP 5, KP 5A. Manual trip function. Adjustment. Setting. Automatic reset. Note: use FINGERS ONLY! (Do NOT use screwdriver). Manual reset. Type. Differential. KP 1, KP 1A. 0.7 bar (10 psi). KP 5, KP
Manual reset. LR 112A. AC 1: 16A. AC 3: 16A. AC 15: 10A. 400 V ?. DC 13. 12 W. 220 V?. Contact 1-4 opens on pressure drop. Contact 1-4 opens on pressure drop. Contact 1-2 opens on pressure rise. Short circuit protection: Fuse 16 Amp. When used acc. to UL regulations. Diff. KP 1, 1A: 0.7 bar (10 psi). KP 5, 5A:.
Man. (Min.) –. SPDT. 060-110366 060-111166. 060-110966. Low. KP 2. -0.2 – 5.0. 0.4 – 1.5. –. –. Auto. –. SPDT. 060-112066 3). –. 060-112366 3). High. KP 5. –. – . 4) Conv.: optional automatic or manual reset. Pressure switch setting with convertible reset. Low pressure. Manual reset1). Automatic reset. Automatic reset.
Manual reset: KP 1, KP 5, KP 7B. HCFC and non-flammable HFC. Mounting. CAUTION: Do not mount the control in a position where dirt, sediment or oil will affect the operation of the control. CAUTION: Do not install these controls on ammonia systems. Mounting requirements. Ambient temperatures t1 min. KP 1, KP 2, KP 5: