20 May 2016 The 2015 IBC also contains additional design criteria for these system types. Note that the codes do not always require compliance with NFPA 92 whenever a smoke control system is required. For example, for smokeproof enclosures (e.g., pressurized stairs and elevator hoistways), the IBC has
A. This section includes the design and control requirements for stairwell pressurization systems. B. Refer to A. The stairwell pressurization system will have a minimum of one fan per stairwell. Provide an isolation Each stairwell fan will also be individually controlled, through the BFAS, by a manual local on-off switch on
It is imperative for the exit stairs to be free of smoke and to incorporate design Stair pressurization. Due to the relative cost of the associated mechanical systems, and architectural space issues related to providing exterior balconies and stair NFPA 92B – Guide for Smoke Management in Malls, Atria, and Large Areas.
6.4.4.4 Manual Override. A manual override switch shall be permitted to be provided at the. FSCS to restart the stairwell pressurization fan(s) after shutdown from the smoke detector. 6.4.5 Controls for Zoned SmokeControl Systems. 6.4.5.1 General. When zoned smokecontrol systems are provided, they shall be activated as.
Figure 4. Multiple injection system with an exhaust fan and a roof mounted supply fan. 18. Figure 5. Multiple injection system with an exhaust fan and several wall mounted supply fans. 19. Figure 6. Typical floor plan for Building No. 1. 20. Figure 7. Diagram of stairwell pressurization system for. Building No. 1. 21. Figure 8.
ommended practice to a standard and to comply with NFPA?s Manual of Style, significant format changes and . ple stair pressurization system, which has performance goals, design objectives, design approaches, and Substantiation: This action is in line with the NFPA Manual of Style which requires that secondary
ble for evaluating smoke control system performance in NIST's investigation of the World Trade Center .. Dedicated Stairwell Pressurization Fan Manual Testing. 213. Sensing Devices. 213. Best Practices. 214. Use of a Single Control System to Coordinate Smoke Control. 214. Control of Devices that are Not Part of the
Mechanical stair pressurization is a preferred system for staircases in high-rise buildings to control the smoke movement The factors that influence the performance of the pressurization system in the stairwell are closely linked to the pressure 2014,. 2214-398x. 3. Walton, G.N and Dols, W.S. CONTAM 3.0 User Guide.
Some guidance documents for pressurization design recognize this practical height limit, such as the ASHRAE Design Manual for Smoke Control [10]. This leads to recommendations that in very tall buildings, the stair enclosure may need to be split into a series of stacked, but separated shafts. However such guidance is not
An engineered system that uses mechanical fans to produce pressure differences across smoke the system shall. • stop air moving fans. • activate exit stair shaft pressurization fan. • activate elevator Vestibules (door hold opens / press.) • activate the vestibule air supply Overriding manual controls for the smoke control.