Instrument name/First year sold, BFT II/1999. Number of units installed in U.S./Outside U.S., —. Number of contracts signed between 1/1/16 and 11/15/16, —. Country where analyzer designed/Manufactured, Germany/Germany. Operational type, batch. Reagent type, open reagent system (reconstituted manually). Operates
COAGULATION. ANALYZER. OPERATION MANUAL. Instrument manufactured by. Sigma Amelung,. Lemgo, Germany. REVISION DATE 10/23/01 .. EXTRINSIC FACTORS II, V, VII AND X FAST TRACK . . Intended Use. The KC4 ?™ Coagulation Analyzer is a semi-automated mechanical clot detection system designed
The BFT II Coagulation Analyzer is a semi-automated, dual-channel coagulometer designed for low volume laboratories.?
by automating manual steps with highly flexible, compact configurations for efficient space . BFT™ II System. The BFT II Analyzer combines the advantages of mechanical and photo-optical clot-detecting principles by employing a unique . high-volume coagulation analyzer and latest addition to the Sysmex. CS family of
Compare Products Now Once Siemens Healthineers, BFT II Coagulation analyzers, January 2017 Contact Information manual: Model type: benchtop: Dimensions. Siemens Healthcare Diagnostics, BFT II Siemens Sysmex technical manual An Siemens S9vt1s Service Manual is vital for the Siemens healthcare service
1 Jan 2009 12–15 months. Walkaway capacity: No. of specimens/No. of tests. —/—. 32/30. 8/8. Min. sample vol. aspirated precisely at one time manual pipetting. 5 µL 847-267-5383 www.siemens.com/diagnostics. Instrument name/first year sold. BFT II/U.S.: 1999. Sysmex CA-530/2006. Sysmex CA-560/U.S.: 2003.
Total efficiency. Stores reference curves; Automatic result calculation, e.g., PT in sec, % of norm/ PR/ INR, Fibrinogen in mg/dL or g/L; Temperature controlled incubation block for reagents and samples; Sample mixing during measurement. Ease-of-use. Light protection cap reduces the risk of user errors by keeping the
Dimensions. Approx. 200 mm x 300 mm x 100 mm (W x D x H). Weight. Approx. 3.8 kg. Onboard Capacity. 4 reagents including 1 reagent mixer. Incubation block for up to 30 cuvettes. Throughput. Approx. 60 PT tests/hour. Approx. 30 APTT tests/hour. Sample Handling. Manual sample pipetting. Reagent Handling. Manual
Siemens Healthcare Diagnostics conduit une action corrective due a une erreur d'impression dans le manuel de reference de l'analyseur BFT II versions 3.00, 3.01 et 3.02 concernant les fiches d'application des facteurs de coagulation endogenes. L'erreur d'impression engendre un risque de rendu de resultat errone, pour
The BFT™ II Analyzer combines the advantages of mechanical and photo-optical clot-detecting principles by employing a unique turbodensitometric detection device. The semi-automated, dual-channel coagulometer is ideal for low-volume laboratories performing routine coagulation tests.