Saturday 25 November 2017 photo 14/15
|
Isotech micro k manual: >> http://ufa.cloudz.pw/download?file=isotech+micro+k+manual << (Download)
Isotech micro k manual: >> http://ufa.cloudz.pw/read?file=isotech+micro+k+manual << (Read Online)
Isotech have a range of innovative precision thermometers to match the calibration . one of the microK's most exciting features, it is inherently drift free. It doesn't . Expandable. Add up to 90 expansion channels. Probes Supported. PRT's, Thermistors & Thermocouples. Units. Ratio, V, ?, °C, °F, K. Switching. Solid state.
one of the microK's most exciting features, it is inherently drift free. It doesn't have compensation or adjustment circuits, it Display Modes. - Numeric and Graphical. - Ratio, Resistance, Voltage, °C, °F, K. ? Stable resistance with no manual correction, this feature is available on the microK 70 and 125 models. Low Noise.
The new microK family of precision thermometers set new world standards for accuracy and stability. Designed for a wide range of high accuracy industrial and scientific calibration applications, the instrument uses a completely new measurement technique to achieve accuracies better than 0.1 parts per million (ppm)
With the ADC's low noise contribution, the microK's overall noise performance is determined primarily by the input noise of the amplifier used to sense the small voltage developed across the PRT. This noise is generated by the amplifier's and look for the next technical challenge? Posted by Isotech at 02:34 No comments:
Different manufactures claim performance in different ways and it can be confusing to compare specifications. With the availability of the automatic resistance bridge calibrator more and more bridges are being calibrated with reports published, the microK is consistently shown to exceed its specification, which is not the case
Accurate:The microK range of precision thermometers employs a completely new type of sigma-delta ADC to provide measurement uncertainty that is quite simply the best in its class. (0.4ppm for K-400 or 0.8ppm for K-800). Stable:The inherently stable 'substitution technique' used in the microK means that it achieves zero
microK 400. Precision Thermometry Bridge: +/-0.4ppm. TTI 2. Accuracy: 0.4ppm maximum over whole range for SPRT with Ro ? 2.5?. (equivalent to 0.1mK at 0°C, or 0.4mK over full range). microK Data Sheet · microsKanner Channel Expander Data Sheet. Accuracy ±0.4ppm; Zero drift for PRTs; PRT, thermocouple
7 Mar 2011 User Manual. Issue 1.05. Applies to: microK 100 and microK 200. Software version 1.4.7+. Firmware version 1.16+. Isothermal Technology Limited. Pine Grove. Southport. Merseyside E: info@isotech.co.uk. W: www.isotech.co.uk should be changed before using the micro application to ensure
This equates to a temperature measurement accuracy of 5 micro K for a 25.5? SPRT referenced to a 25? reference resistor. Manual or automatic bridge balancing together with manual or automatic control (IEEE interface) of the instrument ensure that the F900 can provide solutions in a wide range of measurement
Innovative Thermometry Bridges for Primary and Secondary Laboratories. Accuracy to < ±0.02ppm. Support thermocouples as well as SPRTs, drift free with scanner option.