steam turbine driven chiller efficiency
=========> Download Link http://lopkij.ru/49?keyword=steam-turbine-driven-chiller-efficiency&charset=utf-8
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ing how to apply non-electric chillers to reduce consumption of on-peak, high- cost electricity. Choices of electric and steam chillers are summarized in Table 1, which com- pares overall efficiency (integrated part- load value [IPLV]) and capital cost. Because we are comparing chillers pow- ered by different energy sources,. Chiller compressors can be driven by electric motors, reciprocating engines, gas turbines, or steam turbines. The selection of alternative drive technologies rests. Logically, condensing steam turbines are more expensive and less efficient than the back pressure designs. When site steam requirements are reasonably. Steam Turbine-Driven Chillers: Integrated CHP Systems Corp. and York International are working together to advance the efficient use of steam turbine-driven chillers using gas turbine exhaust and other waste heat streams. ICHPS is taking the lead working with gas turbine manufacturers like Solar Turbines and Kawasaki. KD71750090 - 14 - 0.6 - 33192C - F S. Chiller Model. Evaporator Code. Condenser Code. Compressor Code. Steam Turbine Base Model. Steam Condenser... Overall chiller efficiency cannot be determined by analyz- ing the theoretical. EFFICIEnCY. The YORK compressor, driven by a Murray Turbo-. 10,000 tons of steam turbine driven chillers. University of North. Options: Electric vs. Steam Turbine Driven Chiller. Peak Load. Conditions. Electric. Chiller. Steam Turbine. Drive Chiller. Chiller. 0.50 kW/ton. 11 LBS steam/ton. Auxiliaries. Generation on-line and loaded quickly, efficient, cost effective. • Potential benefits of. YST Steam Turbine Centrifugal Chiller - Chillers - HVAC Equipment. Model Number: #YST Steam Turbine Centrifugal Chiller. The perfect choice for large combined-heating-and-power (CHP) plants, our YORK® YST Steam Chiller ensures that CHP efficiency is maintained year-round, which means less carbon dioxide and. Absorption vs. Electric Chiller. Technologies. Evans J. Lizardos, P.E.. President. LEED Accredited Professional. Lizardos Engineering Associates, P.C.. OCF – Operating Cost Factor x. EF – Efficiency Factor x. EC – Energy Cost. = AOEC – Annual.. •Steam turbine driven centrifugal. •Screw versus centrifugal. •Licensed. 25. Steam Turbine Chillers. • High & Low Temperature Activation, 307 – 600 F. • High & Low Pressure Steam System, 60 – 300 psig. • High Efficiency. Absorption Chillers. Single stage. 0.71. 0.64. Two stage direct fired. 1.00. 0.91. Two stage steam fired. 1.30. 1.19. Steam Turbine Driven Centrifugal Chiller. a MAXE YST steam-turbine-drive chiller from YORK®. Get off the grid with the hottest. Get off the grid with the hottest. Steam-Plant Load. Steam-Plant Efficienc. S. O. N. D. Efficiency. Steam Plant with. YST Chiller: Load. The use of a MAXE YST steam- driven chiller improves cogeneration system and boiler plant utilization. The thermodynamic cycle of an absorption chiller is driven by a heat source; this heat is usually delivered to the chiller via steam, hot water, or combustion. Compared to electrically powered chillers, an absorption chiller has very low electrical power requirements - very rarely above 15 kW combined consumption for both. 4 min - Uploaded by MCW Group of CompaniesThe YORKW!SE Energy Conservation & Retrofit Project was York University's answer to the. Steam turbine chillers were created in order to offer highly effective performance in situations of both design as well as off-design. They are designed to maximize the potential of the varying speed capabilities of the steam turbine and then smoothly deliver high chiller speed and increasing efficiency of. McQuay Distinction™ chillers use a flooded type evaporator, which is very energy efficient.... If the prime mover is a turbine or internal combustion engine, the prime mover's speed can easily be changed.. For cogeneration applications where waste steam may be available, turbine driven chillers can be a good fit. UCI. Substation. 66kV/12kV. Edison. MacArthur. Substation. 66kV. Central Plant: 8 chillers. Gas turbine: 13.5 MW. Steam turbine: 5.6 MW. Solar Rooftop PV. 3.6 MW. TES. Campus Utilities. Chiller Efficiency, Electric Chillers = Input Power to. Compressor (kilowatts) / Cooling Output (Tons), or. kW/ton. • Chiller Efficiency, Steam Driven Chillers = Input. Steam to Turbine Drive (pounds per hour) / Cooling. Output (Tons), or pounds steam per hour/ton. • Chiller COP (Coefficient of Performance) =. This chiller provides a refrigerant enhancement and absorbent concentrator unit that increases the efficiency of absorption chillers, in any one of the generally... Accordingly, the chiller C1 is driven by the gas turbine GT through clutch 20, while the co-generator CG is driven by the steam turbine ST through clutch 23, all as. High-pressure steam turbine or absorption driven chillers. (or, to a lesser extent,. partly by the efficiency of the systems.. steam chillers. Utility steam use aids in meeting NYC's clean air goals through more rigorous control and monitoring of CO2,. NOX, and SO2 than do equivalent capacity central or local. This System Description has been designed to assist you in meeting the requirements of Module. UVM-CP-24 of the Central Heating and Cooling Plant Operator Training and Certification. Program. It contains information about the Chiller Generator System Unit 1 and 2. This includes system purpose, flow path, and details. The configuration on the bottom is a traditional combined-cycle system matching a gas turbine-driven chiller with a steam turbine-driven chiller.. In this arrangement, the turbine remains at full load under most or all conditions and can operate for a majority of the hours in the year under peak efficiency. The value of shaft. Steam from boiler 4 can also be used to drive the steam turbines, although this option was never employed during our 1-year study. If boiler 4 were utilized, the inlet pressure to the steam-driven chiller turbines would be 115 psig, which would lower the chiller efficiency. Data for the steam-driven chillers were collected for a 1. Gas Cooling Options: Absorption, Engine-Driven and Steam Turbine. Absorption systems rely on a cycle of condensation and evaporation to produce cooling. The process is driven. and efficient natural gas energy solutions that are right for your business. NATURAL GAS. Engine driven chiller system. Photo courtesy of. Learn about About Industrial Steam Turbines - Kawasaki Heavy Industries, Ltd. "Powering your potential.". Comparable performance to HFC chiller by developing highly efficient and high pressure ratio compressor under a vacuum condition.. Link. [Techno Box] Kawasaki Water-Refrigerant Centrifugal Chiller outerlink. Liquid Fuels. Natural Gas. Oil Meter. Power Plant. Campus Border. Xfmr. Campus Building. Chiller Plant. 6. “Electrical Energy" Terminology... 20. 58. Using Steam To Make Chilled Water. Steam Turbine Driven Compressor. Absorption Chiller. 59. “TON" of cooling. Rate at which heat is being removed from. CHP Recaptures Much of that Heat, Increasing. Overall Efficiency of Energy Services…… Fuel. Fuel. 30 units. Power Plant. 32% efficiency. (Including T&D). Onsite Boiler.. TURBINE CHILLERS. • Use exhaust heat steam to produce chilled water for air conditioning. • Range: 1500-5000 tons. Heat-Driven Chillers (Turbine). LARGE STEAM TURBINE DRIVEN CHILLER PLANT by. Daniel R.. 9. 3.1.1 Tower Model Verification. 13. 3.2 Steam Turbine Model. 14. 3.2.1 Steam Turbine Verification. 21. 3.3 Chiller Model. 22. 3.3.1 Mechanical Cooling. 23... Figure. (3.5) shows the turbine efficiency as a function of RPM at constant steam flow rates. Steam from turbine extraction; Flash Steam; Low pressure vapours from process. Double effect steam driven absorption machines are one of the most efficient cooling solutions for industrial applications.. Thermax double effect absorption chillers are designed based on its proven Advanced Series Flow technology. One of NYP-Columbia's long-term energy initiatives is continuous improvement of its chiller plant operations. The 8,800-ton central plant serving the 4,000,000-sq-ft campus in New York City comprises seven York chillers – three 2,000-ton steam-turbine-driven chillers, three 2,000-ton electric-motor-drive chillers (one with a. ergy efficiency, increased site resiliency and envi- ronmental responsibility, similar to the successful. Ultimately the team proposed a hybrid chiller plant with a refurbished steam turbine chiller and a new electric centrifugal chiller with a connected thermal storage system. The new electric chiller would be a dual-mode. You could maybe set up an absorption chiller and modify the efficiency and curves to reflect the steam usage of the chiller you are trying to model.. Behalf Of Janne Kairento Sent: Friday, May 13, 2011 11:52 AM To: equest-users at onebuilding.org Subject: [Equest-users] Steam turbine driven chiller Hello. In trigeneration systems, however, this steam could otherwise be used to generate electricity. Since double-effect chillers have a higher temperature fuel source, they are more efficient than single-effect chillers. As the hot refrigerant is driven off by the hot steam, it passes through a heat exchanger to. With a range of engines and turbines that can serve as air compressors, blowers, chillers, and pumps, GE Power Generation excels in mechanical drive. Find out more here.. The engine or turbine-driven compressor pulls air in, compresses it, and pushes it into a storage tank to a maximum allowable level. When a tool is. Find Steam Turbine Driven Centrifugal Chillers related suppliers, manufacturers, products and specifications on GlobalSpec - a trusted source of Steam Turbine Driven Centrifugal Chillers information. A loss of vacuum or drift by as little as .35"Hg will find the steam consumption to the turbine increased by about 1.0 %. Therefore, a 1200Tr Steam Turbine Driven chiller in a NY commercial building application left operating a season with 22"Hg and 40psi inlet would find a loss in efficiency of over 10% and an impact to cost. It can be seen from the definition of Carnot efficiency, that increasing the lift (TO – TR) lowers the. COP. This single. Using typical chiller operating conditions yields a Carnot efficiency of 0.348 kW/ton. No chiller... For cogeneration applications where waste steam may be available, turbine driven chillers can be a good fit. such as boiler feedwater pumps, process pumps, air compressors and refrigeration chillers. Such.. influence of steam turbine discharge pressure on power output and, consequently, net heat rate and efficiency.... In general, steam turbine applications are driven by balancing lower cost fuel or avoided disposal costs. A control system and method are provided for the automatic startup and shutdown of a steam turbine driven chiller unit. The chiller. Preferably, steam turbine 14 is a multistage, variable speed turbine that is capable of operating compressor 12 at a speed that more closely optimizes the efficiency of the chiller system 10. back pressure steam turbine generator (exhaust steam at 150 psig) and three steam-turbine-driven centrifugal chillers. Part of 600-psig steam is supplied to the west plant directly. The processed steam (at 150 psig and 20 psig respectively) supplies heat for the. using the most efficient load combination of boilers, turbines. Boiler and Chiller Plants, holding New York City Licenses to operate High Pressure Steam and Refrigeration.. (3), 2,000-ton steam turbine driven chillers, two, 2,000-ton electric motor driven chillers, primary and... Woodland, CA. Feasibility study to improve the energy efficiency of this 10.4 MGD waste water treatment. I want to correct some of the information I just put out there regarding steam-turbine driven chillers. At 150 psig, the steam temperature is about 350F, which corresponds to a maximum thermodynamic turbine efficiency of about 30%; mechanical efficiency would lower this. And the steam turbines used in chillers have better. The analysis assumed 125 psig dry and saturated entering steam, and leaving at an exhaust vacuum of 3" to 4" of mercury absolute (HgA) with moisture content of about 10%. This information was obtained from both chiller and turbine manufacturers. No Heat Recovery Benefit was Assumed with the Gas- Engine Driven. Steam Rate. Source: Columbia University. Table 2. New Electric Chiller, Old. Powerhouse Chiller Plant. Chiller Type. Steam turbine. Steam turbine. Steam turbine.. Design Steam Flow. Nonstandard Part-Load Value. Steam Rate. Full-Load Steam Rate. Source: Columbia University. Table 3. New Steam-Driven Centrifugal. The existing CSHP chilled water system includes two 4,000 ton and two 8,500 ton steam condensing turbine driven centrifugal chillers and one 1000 ton low. capacity with new 5500 ton efficient dual compressor electric chiller replacing one of two of the older 1973 less efficient 3500 ton steam turbine driven chillers, the. MU generates electricity with two 13 MW gas combustion turbines and four backpressure steam. the campus in part through steam driven absorption chillers, MU refers to its system as a. optimizes the campus cooling load by operating the most efficient chillers first, reducing the energy to cool the campus. Quick Facts. The hot water or steam, in turn, is used to provide thermal energy to heat buildings, or to drive equipment such as absorption or steam turbine driven chillers. By using the already hot exhaust gas from a prime mover, the combustion efficiency of the duct burner is higher than normally achievable with a conventional boiler. Steam Turbine Centrifugal Chillers Rajesh Dixit Global Product Manager for Thermally Driven Chillers, Johnson Controls, Inc. Rajesh is a Chemical. He is currently responsible for global product management for thermallydriven cooling, heating, and power products of Johnson Controls (Building Efficiency). steam and electricity. The chiller is run from May through the end of October to support UCSD's summer cool- ing load. The size of the chiller necessitates this seasonal usage because its operating efficiency drops under partial loading condi- tions. Spring and fall are typically mild in San. Diego, which reduces the campus's. All chillers and chilled water distribution systems are maintained on a regular basis to ensure the highest available efficiencies. The total capacity of. The chiller will either be an absorption chiller or steam turbine driven centrifugal, and the remaining single stage absorption chiller will be demolished. Study the economic. The installation of the cogeneration turbine with duct burner and high pressure steam thermal energy recovery unit (HSRG). reduced energy mix cost and to increase CHP thermal efficiency while in the Cogeneration. (CHP) mode.. addition of a 2,800 ton steam turbine driven chiller and by revision of the existing electrical. 3 The utilization of waste heat from the turbine to off- set its low efficiency when based on shaft power alone... specific gas consumption versus tonnage for a turbine-driven centrifugal/absorption system of 1000 tons.. we have substituted a steam turbine, condenser and a large centrifugal chiller for the absorption system. In addition, parametric study indicates the effects of different parameters, such as steam to gas mass flow rate ratio, fraction of steam extraction from the exhaust of LP line in HRSG for the generator of absorption chillers and inlet LP and HP steam turbine temperature on the performance of present power. R.M. Thornton delivers mechanical contracting projects of uncompromising quality in and around Maryland, Washington DC, and Virginia. From facilities service contracts to the most complicated commercial HVAC installations, repairs and retrofit projects, R.M. Thornton exceeds expectations by every measure. For over five decades, Carrier's 17DA centrifugal chillers have been the equipment of choice for large tonnage (3,000-5,500) applications where performance and energy efficiency are prerequisites. They're specified for municipal. steam turbine (whichever proves to be the most economical for your specific installation's. (Facility). Supplier Side. (Power Plants and Engines Room). Efficient Operation by Utilizing IT. Electricity. Gas. Turbine. Generator. Steam. Heater. Extracted Steam. Steam. Exhaust. Heat. Boiler. Fuel. (NLG). Extraction. Condensing. Steam Turbine. Generator. Steam. Heater. Steam driven. Chiller. Heating for. Cleansing. mixture chillers. A single-effect absorption chiller (lithium bromide and water mixture) can use hot water at least 180°F or 18 lbs/h of steam at 15-psig per RT... chiller could be driven by an electric motor, natural gas engine, or steam turbine. When a mechanical chiller is operated by an electric motor, it requires electric. of an integrated package of energy efficiency measures and renewable energy systems that will maximize net.. turbine, heat recovery steam generator (HRSG), and electric chiller to efficiently meet the growing. the 3 2,500 ton steam turbine driven chillers operate at 250 psig inlet pressure; the 5,000 ton. Water-Cooled, Custom-Design Centrifugal Chiller. 3,000 to 5,500 Tons. For over five decades, AquaEdge® 17DA has been the chiller of choice for large tonnage applications where performance and energy efficiency are essential. The success of the AquaEdge® 17DA is the inherent design characteristics that deliver. That plant had included two 1,100-ton steam turbine-driven centrifugal chillers, and one 400-ton electric centrifugal machine. Steam for the two. The ultimate recommendation of the engineer, and the choice of the owner, was to replace the steam turbine machines with new high-efficiency centrifugal chillers. The economic. Replacing the original steam turbine-driven chillers with high-efficiency variable speed/flow electric-driven chillers. -- Installing a variable frequency drive (VFD) on chilled and condenser water pumps, cooling tower fans, and air handling units. -- Retrofitting bathrooms with high-efficiency flush valves, faucets, and fixtures. The chiller plant project reached its peak on January 31, 2011, when two new, ultra-efficient water chillers and pumps were delivered into the powerhouse. The 2,800-ton chillers-one driven by a steam turbine and one by an electric motor-will give the University the flexibility to draw on either steam or electric power, thereby.
Annons