If you mean that the zone valve is not opening and your radiators are not getting hot water, then you might try an manual override of the zone control valve. Caution: be sure you read the directions on how to do that. I think you may have to disconnect one or two wires from the valve before you attempt the manual override.
2 Dec 2011
This is the Taco zone valve. The head on yours may be blue green instead of gold or brown. The top (#1) terminal is the power to the zone valve The middle (#2) terminal is the common terminal. The button (#3) terminal is the end switch. 24 volts to 1 and 2 opens the zone valve. If the thermostat is turned all the way up and
Taco Zone Valves Turn t-stat up. Check for 24 VAC across terminals 1&2. If there is power there, wait a few minutes. Feel the manual open lever on the head. The resistance to you moving it should decrease as the valve opens, until the lever goes up and down easily, when valve is fully open. At this point you should begin
I use wire nuts, didn't what they're called. It sounds like the result of your suggestion would be to disable the zone valve. If that's correct, then when happens? Do I go from too much heat in that zone to none? Rickheatdoc : Yes you would have no heat in that zone. You could open the the valve manually (pull the lever on the
I have a ranch house with a two zone oil heat system. House is built 1972, Utica boiler is from early nineties. One zone is to the front of the house.
Plant ID. No. 001-302. APPLICATION. The Taco-Zone Valve is an electricity operated valve used for zone control of Hydronic Heating 568 Taco Thermostat (designed specifically for Taco-Zone Valves) with Heat Anticipator set at “ D ". Other suitable two wire maximum of 3 Taco-Zone Valves. MANUAL OPENING LEVER.
5 Feb 2011 Taco makes a range of heating and cooling products, including a Taco zone valve. The zone valve works with hot water or steam-based baseboard heating systems. When a Grasp the small silver lever on the side of the Taco valve and push it all the way down going from "Auto" to "Manual." If there is
6. Position new Taco replacement power unit on valve body, push down slightly and twist counter-clockwise to assemble onto valve body. 7. Reconnect wires marked 1, 2, and 3 to their respective terminals on the replace-ment power unit. 8. Check to make sure that the manual operation lever is in the auto