8 Oct 2007 The full classification includes classes E1, E2, F1, F2, M1, M2, and M3 in tiers of uncertainty or tolerances - for example a Class E1 weight would normally be used as a standard for the calibration of a Class E2 weight (of the same nominal mass). The OIML recommends model criteria but it does not have
Qualification of Balances. Annex 8 to the OMCL Network Guideline “Qualification of Equipment". PA/PH/OMCL (12) 77 7R. Document type. Guideline Analytical Balances. 4. I. 5. Precision Balances. 1 to 3. II. 6. Technical Balances. 0 to 1. III. The classifications are based on the OIML R 76-1 International Recommendation
2 Jan 2009 Recommendation OIML R 111 [4] should satisfy all these requirements. The maximum permissible errors, or the uncertainties of calibration of the standard weights shall be compatible with the scale interval d [3] of the instrument and/or the needs of the client with regard to the uncertainty of the calibration of
Partie 1: Exigences metrologiques et techniques - Essais. OIML R 76-1. Edition 1992 (E). Note: This pdf document INCLUDES: - Amendment 1 (1994) Scale base. An imaginary line through the centres of all the shortest scale marks. T.2.5. Auxiliary indicating devices. T.2.5.1. Rider. Detachable poise of small mass that
ity (?) are sufficiently small, and the balance is calibrated with reference weights of well known mass, the balance can be used to indicate the conventional mass, m c. , of a body under conventionally chosen conditions. 2.3. Calibration. Set of operations that establish, under specified conditions, the relationship between
Calibrating. Standard Weights. Introduction. Reliable weighing depends on the use of standard weights of known mass value. Standard weights are used to calibrate the balances used for weighing, to specification for standard weights is OIML R 111-1 [1], the difference between balance readings for the weight.
METTLER TOLEDO is the world's leading manufacturer of balances and a significant supplier of weights, weight sets and related weight calibration services. The weight portfolio covers both OIML and ASTM weights from. 1mg to several tons in all accuracy classes. Our customers all over the world use our weights for
9 Feb 2015 Class F1 Suitable for use for traceability of OIML class F2 weights and lower; also with OIML accuracy class I weighing instruments. The maximum permissible error from nominal value at 1 kg is ±5 mg. For the calibration of high accuracy class 2 balances. Class F2 Suitable for use for traceability of OIML
test of balances in laboratory, industrial and production environments. Calibration of other weights. Due to their high quality, the METTLER TOLEDO Weights are ideal as primary mass standards to calibrate other weights of lower class of accuracy. Fulfil OIML R111-1. METTLER TOLEDO Weights fulfil OIML (Organisation
METTLER TOLEDO is the world's leading manufacturer of balances and a significant supplier of weights, weight sets and related weight calibration services. The weight portfolio covers ANSI/ASTM and OIML weights from one milligram to five tons in all accuracy classes. Our customers all over the world use our weights for