Figure 1. Venturi Meter Operation. The purpose of this paper is to demonstrate two simple and inexpensive laboratory experiments for analyzing the performance of a venturi. These experiments may be performed as laboratory exercises or as classroom demonstrations. In the first experiment, a shop fabricated venturi was.
Lab 2: Venturi Meter. BACKGROUND. A Venturi meter is a tube with a constricted throat that increases velocity and decreases pressure (see Figure 1). Venturi meters are used for measuring The discharge coefficient (Cd), otherwise known as the coefficient of the Venturi meter, typically construct the graph in the report.
Flow Measurement and Losses (Venturi Meter). Objective. The purpose of the experiment is to demonstrate typical flow measurement devices for incom- pressible fluids: (1) Venturi meter, (2) Orifice plate, and (3) Rotameter. Each flow measurement device will be compared to the standard method using the catch-tank and
15 Aug 2003 As you requested in your e-mail of 08/07/03, I have attached a copy of my final report on the Calibration of an Orifice Meter Experiment. Note that discharge predictions from the fundamental discharge relationship and the calibration equation produced errors below the. ± 10% that you had stipulated.
Experiment No.4: Flow through Venturi meter. Background and Theory. Introduction. Flow meters are used in the industry to measure the volumetric flow rate of fluids. Differential pressure type flow meters ( Head flow meters)measure flow rate by introducing a constriction in the flow. The pressure difference caused by the.
Mark wrote the summary and introduction of the report.SUMMARY Even though this topic has not yet been treated in class. . this experiment has enlightened our understanding on the relationship between the rate of flow and pressure with respect to a Venturi meter. 2011. All group members were present and actively
CHE241 - Lab Report Flowmeter Measurement Apparatus FM101 (2015). Nurlina Syahiirah. Uploaded by. Nurlina Syahiirah. connect to download. Get pdf In short, the apparatus allows the following experiment to be carried out: a) A comparison of flow measurement using venturi, orifice, rotameter and bench. b)
The main objectives of this experiment is to obtain the coefficient of discharge from meter and relating the pressure difference to the flow rate yields. Figure 2. Venturi meter. Assume incompressible flow and no frictional losses, from Bernoulli's Equation. 2. 2. 2. 2. 1. 2 .. In your laboratory reports must have the followings;.
PROCEDURE: A schematic of the Venturi meter is shown on the diagram at the end of the procedure. The inlet diameter equals d – 26 mm and the throat diameter d = 16 mm. The pressure along the meter is obtained using the 11 pressure taps at the locations shown on the diagram. The water flow rate can be adjusted
Lab Report for Venturi Meter - Free download as PDF File (.pdf), Text File (.txt) or read online for free.