17 Nov 2017 AWG Wire Sizes (see chart below). AWG: In the American Wire Gauge (AWG) system, diameters can be calculated by applying the formula D(AWG)=.005·92((36-AWG)/39) inch. For the 00, 000, 0000 etc. gauges you use -1, -2, -3, which makes more sense mathematically than "double nought." This means
selected using the 10% drop chart is sufficient. For all products, consult the owner's manual for specific wiring instructions and/or size recommendations. www.imtra.com. Conductor Sizes (Gauge) for 3% Voltage Drop - 12 VOLTS. Total Current on Circuit. Length of conductor from source of current to the product and back to
600V Feeder Cdr. Size (AWG/KCMIL). Ampacity at 75° C. Min. Size EMT Cond uit. Min. Size PVC Conduit. (Sch. 40). Copper. Aluminum. Copper. Aluminum. Copper. Aluminum. Copper. Aluminum. 8 - 8 - 8 - 8. 6 - 6 - 6 - 6. 50. 50. 3/4". 3/4". 3/4". 3/4". 6 - 6 - 6 - 8. 4 - 4 - 4 - 6. 65. 65. 3/4". 1". 3/4". 1". 4 - 4 - 4 - 8. 2 - 2 - 2 - 6. 85.
What Type and Gauge of Wire Should I use? Other Major Appliances. Electric Dryer - up to 30 amps. 10/2 with ground. Electric Wall Heater (Over 1650 Watts at 120v). 8/3 with ground. Double Oven Range - up to 45 amps. 6/3 with ground. Built-in Double Ovens - up to 50 amps. Double Oven Range - up to 60 amps
COPPER WIRE CURRENT CAPACITY Single wire in open air, ambient temperature 86oF. Ampacities of Wire Types (w/ Temp Rating) @ 0-2000 Volts. Wire Size AWG, TW UF (140oF), FEPW, RH, RHW, THW, THWN, ZW, THHW, XHHW (167oF). USE-2, XHH, XHHW, -2, 0000. 000. 00. 0. 1. 2. 3. 4. 6. 8. 10. 12. 14. 16. 20
500. Copper Wire Size. Selection for Long Runs. 25'. 110 Volt, Single Phase, Max 3% Voltage Drop*. Length of Run. 50. 100'. 1501. 2001. Amp Load. 12. 15 AMP. 10. 8. 20 AMP. 14. 8. 12. 10. 8. 6. 30 AMP. 3. 3. 3/0. 1. 2/0. 3/0. 100 AMP. 3/03/O. 250 MCM. 350 MCM. 200 AMP. 220 Volt, Single Phase, Max 3% Voltage Drop*.
Ampacities of Insulated Conductors (From NEC Table 310-16) Not More than Three Conductors in Raceway or Cable or Earth (Directly Buried) (Based on Ambient Temperature of 30° C, 86° F). Size, Copper Conductors, Aluminum Conductors Copper-Clad Conductors. 60° C (140° F), 75° C (167° F), 90° C (194° F), 60° C
3 or 4, 2 3, 13 Amps 10 Amps, 10 Amps 7 Amps, 600 Volts AC. 14 AWG, 2, 3 or 4 3 or 4, 2 3, 18 Amps 15 Amps, 13 Amps 10 Amps, 600 Volts AC. 12 AWG, 2, 3 or 4 3, 4 or 5, 2 3, 25 Amps 20 Amps, 18 Amps 15 Amps, 600 Volts AC. 10 AWG, 2, 3 or 4 3, 4 or 5, 2 3, 30 Amps 25 Amps, 25 Amps 20 Amps, 600 Volts AC. 8 AWG
You must use the correct size wire for the amperage requirement of the circuit to prevent the wire from over heating. 8. 40. 50. 55. 40. 45. 6. 55. 65. 75. 50. 55. 4. 70. 85. 95. 65. 75. 3. 85. 100. 115. 75. 85. 2. 95. 115. 130. 90. 100. 1. ---. 130. 145. 100. 115. 1/0. ---. 150. 170. 120. 135 DOWNLOAD AMPACITY CHART PDF
For 3-wire 120/240 and 120/208V residential services or sub-services, the allowable ampacity for sizes #6, #2, and #4/0 AWG aluminum shall be 60, 100, and 200 amperes respectively. #2/0 AWG copper shall be 200 amperes. In these cases, the 5% adjustment per C.E. Code rule 8-106 (1) cannot be applied.