Install in the floor area as close as possible to the centre. ? Distance from floor panel. > 100 mm. ? Place heaters below the compo- nents to be protected. ? Distance from side panels. > 50 mm. ? Distance from thermoplastic materials > 35 mm. ? In case of excessive air humidity, a hygrostat should be used to achieve.
10 Feb 2014 Hygrostat – SK 3118.000 created : 10.02.2014 on www.rittal.com/com-en. Product description. Description: The hygrostat switches on the heater and/or fan when a preset relative humidity in the enclosure is exceeded. In this way, the relative humidity is raised above the dew point, and condensation on
Internal temperature displays and thermostats, hygrostats, speed controls, and more for climate control. Control/Regulation. We offer a wide range of control and regulation accessories for heating & cooling, climate control, and air conditioning systems and enclosures. Digital Enclosure Internal Temperature Display and
Hygrostat – SK 3118.000 created: 12.07.2016 on www.rittal.com/com-en. Product description. Description: The hygrostat switches on the heater and/or fan when a preset relative humidity in the enclosure is exceeded. In this way, the relative humidity is reduced, and condensation on assemblies or electronic components is
Rittal. SK. Hygrostat. Hygrostat. Hygrostat. Hygrostaat. Hygrostat. Igrostato. Higrostato. SK 3118.000. Montageanleitung. Assembly instructions. Notice de montage. Montage-instruktie. Montageanvisning. Istruzioni di montaggio. Instrucciones de montaje. U 468. 931. 002. 555-1. Rittal-Werk · Rudolf Loh GmbH & Co. KG.
142. 170. 101. Rated operating voltage Volt, Hz. 110 or 230 V, 50/60 Hz. Continuous thermal output at Tu = 10°C. 250 W1). 400 W1). 800 W1). Pre-fuse gG for 110 V. 4 A. 6 A. 10 A. Pre-fuse gG for 230 V. 4 A. 6 A. 6 A. Accessories. Packs of. SK (hardcover), page. Thermostat. 1. 3110.000. 178. Hygrostat. 1. 3118.000. 178.
Rittal enclosure heater assembly instructions. EN. Contents. 1 Notes on documentation . . . . . . . 3. 1.1 These assembly instructions are aimed at. – tradespersons who are familiar with assembly and installation of the by incorporating a hygrostat (3118.000). 3.2 Proper use. Rittal heaters were developed and designed.
254. PARTIALLY. INTERNAL. MoUNTING younting N?. ? 200. |. * only FoR. INTERNAL. SK3370.910. SK3370.912. SK3370.916. SK3370.920. 350.0 o. SK3370.910. SK3370.912. SK3370.916. SK3370.920. 400.0. 370.0. 320.9. *1204.) Door Limit Switch. Rittal Compact Cooling Units. Hygrostat. Spare filter mats. Condensate
The hygrostat switches on the heater and/or fan when a preset relative humidity in the enclosure is exceeded. The relative humidity is raised above the dew point and condensation on assemblies or electronic components is avoided.
Adjustable. Brand. Rittal. Activation Humidity. 50 > 100%RH. Mount Type. Screw. Supply Voltage. 24 > 230 V ac/dc. Minimum Humidity Setting. 50%RH. Select all. Find alternative products. Technical Reference. RoHS Certificate of Compliance. Statement of conformity. Similar Products. Similar Products. Found an error?