F Series Cabinets &. Counters with. AT1-5 & AT2-5. Controllers. Operation. , Installatio n. & Service Manual. Issued June 2011 The F range consists of a choice of capacities and temperature ranges in the Gastronorm format, accommodating. GN2/1 (650mm x 530mm) or Input NTC 10K?@25°C, LAE part No. SN4.
Increase Button / Manual Activation. Defrost Output. Stand-by Button. Activation of 2nd parameter set. Symbol. Reason. Symbol. Reason. Defrost in progress. Condenser high pressure alarm. Controller in stand-by. Room high temperature alarm. Condenser clean warning. Room low temperature alarm. Door open alarm.
Locate the LAE Controller Display on your specific case. It is typically located near the the controller to normal operation. All parameters are now returned to the default factory settings. . ABS - the values programmed into parameters ALA and AHA represent temperature alarm limits. REL - the values programmed into
31 Mar 2016
controller is locked. LAE Control. Info / Set Point. Button. Manual Activation. Up Button. Manual Defrost /. Down Button. Stand-By. Button. LAE Control Icons. Compressor Running. Activation of 2nd Parameter Set. Alarm. Cabinet in Defrost. Evaporator Fan Running. LAE ELECTRONIC TEMPERATURE CONTROLS
1. BMG/TMG -27, 48, 52, 74, 80. LAE CONTROLLER. Installation & Operations Manual. Master-Bilt Products. 908 Highway 15 North. New Albany, MS 38652 This manual contains important instructions for installing, using, and The store temperature should be at or below 75°F and a relative humidity of 55% or less.
Contacts · Download · News · Company · Comprehensive design · Products · Custom · Controllers · Refrigeration controllers · Compressor controller · Meters · Timer · Supervisory systems · Probes - transmitters · Accessories. SPECIALISTS IN CUSTOMISED PRODUCTS. YOUR ORIGINAL IDEAS NEED TAILOR-MADE
Installation & Operations Manual. LAE – AT2-5 Controller. Master-Bilt Products. 908 Highway 15 North. New Albany, MS 38652 .. Fan The fans will run constantly except when a defrost is initiated, or when the evaporator temp is above the 30oF. When in defrost mode the fan is off until the end of the defrost and the 2
We thank you for choosing an LAE controller. The adaptation of the controller to the system that it controls is achieved through the parameters in the setup. 255 air temperature manual defrost waiting for peripheral start sequence address. DEF. AL. A H. ---. --- defrost on alarm sources high . temperature. ALR. T1. -18.
DISPLAY. During normal operation, the display shows either the temperature measured or one of the following indications: DEF Defrost in progress. HI Room high temperature alarm. REC Recovery after defrost. LO Room low temperature alarm. OFF Controller in stand-by. E1 Probe T1 failure. CL Condenser clean warning.