KAST-O-LITE 30 LI Plus is a high alumina, lightweight, 3000°F maximum service temperature, insulating castable. It exhibits moderate density, excellent strengths, low iron, and low thermal conductivity. Typical applications are aluminum furnace stacks, aluminum holding furnace doors, reheat furnace discharge doors,
Kastolite 30 Mixing And Dry Out Instructions. The following is given in good faith for Guidance only. **Before attempting to mix refractory, be sure to wear proper personal protective equipment such as eye protection, appropriate dust mask, and disposable gloves. Mix outdoors or in a well ventilated area. When mixing add
1 Oct 2008 Mixing & Using Instructions. KAST-O-LITE 30 LI G. General. Material should be stored in a dry place. For best results, material should be maintained at. 10 - 21°C prior to gunning. This product is designed to be gunned using standard gunnite equipment by experienced personnel. All equipment used to mix
26 Aug 2014 It came with two 55# bags of A.P. Green Kast-O-Lite 26li refractory and I am ready to mix and install it. Does someone have or I finished one of my "lionels" a little while ago, although I used the 30_li (3000 temp), I can offer this- in his kit instructions, he has a firing schedule for it. I chose to let it sit for at
19 Aug 2012 Kast-O-Lite 30 LI seemed like it fit the bill with a maximum use temperature of 3000F which is not something I am likely to reach unless I am over boiling I mixed this in a big 5 gallon bucket with a mixing attachment to my power drill. You are supposed to mix for 3 minutes and then cast within 10 minutes.
1 Oct 2008 Mixing & Using Instructions. KAST-O-LITE 30 LI. General. Material should be stored in a dry place. For best results, material should be maintained at. 10 - 21°C prior to casting. Porous back-up materials or wood forms should be waterproofed. Absorption of water can result in reduced flow or affect setting of
Description. KAST-O-LITE 30 LI Plus is a high alumina, lightweight, 3000°F maximum service temperature, insulating castable. It exhibits moderate density, excellent strengths, low iron, and low thermal conductivity.
Which % Kast-O-Lite did you pick up? After the input by folks here I decided to go with Kast-O-Lite 30. I haven't looked the bag over though so we may be in the same boat looking for mixing directions. We want it as dry as possible and still get it to fill the form completely. If you're going to use it in a trowel on
Frequently Asked Questions. Mizzou Castable Refractory: This is a 3000 degree F, High Alumina Castable Refractory for making forges. You can cast the entire refractory liner for a forge or just the floor using this material! This material has a very high resistance to flux, if you're doing a lot of forge welding and have a
22 Aug 2012 Kast-O-Lite 30 LI seemed like it fit the bill with a maximum use temperature of 3000F which is not something I am likely to reach unless I am over boiling iron. For general forging, Kast-O-Lite 26 I mixed this in a big 5 gallon bucket with a mixing attachment to my power drill. You are supposed to mix for 3