Did you misplace your user's manual? We have put together a comprehensive guide to help you download the correct user's manual for your product. Start by selecting type of heater or fan from the menu bar to the left. Heating Manuals. Kerosene/Diesel Forced Air Torpedo Heaters · SilentDrive® Kerosene/Diesel Forced
5, 098512-50, Combustion Chamber (55/60) ( No Longer Available ). 6, M10908-2, Screw, #6-32 x 3/8 ". 7, 103154-03, Photocell Bracket. 8, M16656-24, Photocell Assembly Reddy Heaters R60 - 60,000 Btu/Hr. Kerosene Forced Air Heater; R60 Heaters Heat up to 1600 sq. Ft. The 5 Gallon Tank Runs Approx. 9.5 Hours
and nozzle. Requires a winterizing additive at temperatures below 20°F. 3. Ventilation. The heater should be used only in well-ventilated areas. As a rule, the following minimum requirements should be followed. HEATER SIZE (BTU) SQUARE FOOT OPENING. 35,000/40,000. 1.0 Sq. Ft. 50,000/55,000/60,000. 1.6 Sq. Ft.
Desa reddy heater 60 Pdf User Manuals. View online or download Desa reddy heater 60 Owner's Manual.
Desa Reddy R60H Manual (FREE DOWNLOAD). Be the first to write a review. DESA. Reddy. Click here for Model: R60H. 60,000 BTU. For a FREE copy just click on the Red link above and print it yourself. OR. $10 for us to send a printed copy to you. Desa Reddy R60H Manual (FREE DOWNLOAD)
Desa owner's manual propane construction convection heater 30-80,000 btu/hr, 75-200,000 btu/hr (32 pages). Heater Desa RCLP30 Owner's Manual. Kerosene/diesel portable forced air heaters 40,000 50,000 55,000 60,000 70,000 110,000 115,000 155,000 165,000 and 200,000 btu/hr models h.s.i. series (32 pages)
Keep this manual for future reference. Save this manual for future reference. For more information, visit www.desatech.com. HEATER SIZES: 40,000 50,000 55,000 60,000 70,000 110,000. 115,000 155,000 165,000 AND 200,000 BTU/HR MODELS. H.S.I. SERIES. KEROSENE/DIESEL PORTABLE FORCED AIR HEATERS.
As a result, the heater will not run to specs. Instructions for setting the air pump pressure: Air pump pressure is the pulse of the heater. Pump pressures range from 3 psi to 6 psi depending on heater BTU size (see chart below). A loss of ONLY 1 psi translates to a 30% to 17% loss of FUEL FLOW (starvation). You must know
Instructions for setting the pump pressure are at reddyparts.com/pressure.htm . The air pumps on the old style heaters could be adjusted to suit the operator's nose. If the heater smells just adjust the pressure a little until it smells good. Not so with the new heaters- you adjust to suit the computer, not you. Air leak. If there
Jan 22, 2009 Recent Reddy Heater 60000 BTU Kerosene Forced-Air Heater #R60A questions, problems & answers. Free expert DIY tips, support, troubleshooting help & repair advice for all Measuring Tools & Sensors.