Push Button Manual Reset Valves. Brass and 316 Stainless Steel Bodies. 1/4" NPT. 2. 3. 1. U. Solenoid Enclosures. Electrical. Nominal Ambient Temp. Ranges. -4?F to 131?F (-20?C to 55?C). Refer to Engineering Section for details. Approvals. CSA certified. UL listed General Purpose Valves. Meets applicable CE directives.
The ASCO NVR Manual Reset Valve moves to its fail-safe position when de-energized. The valve in the “up" (latched) position will supply the fluid media or vent the fluid media depending on the piping of the installation, then switch when tripped into the “down" (unlatched) position.
ASCO Series 327 Valves. Compact tamperproof / manual reset function which measn that the valve has to be energized as well as manually operated before it stays in the 'latched' position. Because of the tamperproof feature there will be no flow from port 3 to port 2 if only the push button is pressed. These solenoid valves
Valve Parts in Contact with Fluids. Main Valve. Body. Brass. Disc. 303 Stainless Steel. Seats. Phosphor Bronze. Springs. 17-7 PH Stainless Steel. Seals. FKM. Air Operator Diaphragm. FMQ. Bearing Screw. 430 Stainless Steel. Lever. 302 Stainless Steel. Pilot Valve. Body. Brass. Shading Coil. Copper (AC only). Seals.
Solenoid Valve - 3 Way: 3/2 - Series 308 Universal Operation - Manual Reset Valves - 1/4 to 1 - Brass, Stainless Steel - Air: Inert Gas, Water, Light Oil.
Once tripped, can only be manually reset to automatic operation. • Electrically Tripped (trips when energized), No Voltage. Release (trips when de-energized), or Free Handle constructions. • Intrinsically Safe constructions are available. Manual Reset Valves. Brass Body • 1/4" to 1" NPT. Solenoid Enclosures. Electrical.
When tripped, they can be manually cycled open/closed, but must be reset when the solenoid has once again been de-energized. No Voltage Release – Valves move to latched position when the solenoid is energized, trips when de-energized.
No Voltage Release – Valves move to latched position when the solenoid is energized, trips when de-energized. When tripped, they can be manually cycled open/ closed, but must be reset when the solenoid has once again been energized. Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz. 6, 12, 24, 120, 240 volts DC.
ASCO 308-S Series Manual Reset Solenoid Valves. Asco. The ASCO 308-S Series is a line of manual reset solenoid valves with high-flow/high-pressure bodies designed to prevent inadvertent valve start-up. Its intrinsically safe constructions are ideal for controlling critical processes in biofuels and refining applications.