The new CPV valve terminals from Festo are equipped with an IP-link interface (CPV fieldbus node) and can thus be integrated into the piconet® fieldbus system as an extension module. The valve terminals are bus capable and suited for fieldbus systems such as PROFIBUS-DP, CANopen und DeviceNet™. Further bus
Technical data – Fieldbus node CPV-DI01. General technical data. Type. CPV10-GE-DI01-8. CPV14-GE-DI01-8. CPV18-GE-DI01-8. Part No. 165 809. 165 811. 165 813. CP string extension. Yes. 16 inputs and 16 outputs. Baud rates. [kBaud]. 9.6 12,000; automatic detection. Addressing range. Profibus DP (12 MBaud).
CPV valve terminal with field bus direct connection. Types: – CPV-DI02. PROFIBUS-DP. – CPV-CS02. ABB CS31. Compact performance. Manual. 548732 en 1201a. [762106] . Field bus baud rate and field bus length for PROFIBUS-DP (CPV-DI02) . 1-17. 1.3.3 .. 0107 (for sizes CPV10 and CPV14). – CPV-CS02:
Manual overrides for valves .. A bus node or control block also en ables the connection of decentralised input/output units. The following bus protocols are supported: • PROFIBUS DP . 1) Cannot be assembled in conjunction with the control cabinet version of the pneumatic multiple connector plate CPV10-VI-P..
connected via a serial CP string extension. DI01 supports 4 different fieldbus protocols, which are selected by means of DIL switches: • Profibus DP. • Moeller SUCOnet K. • ABB CS31. • Festo fieldbus. The CPV fieldbus node is available in three sizes, with identical perform- ance characteristics: • CPV10. • CPV14. • CPV18.
Manual overrides for valves. • Protection class to IP65 in the control cabinet. • Intrinsically safe valve manifold design to ATEX Category 2 (Zone 1). • Extremely robust thanks to the metal valve design. • Long service life. • Ready-to-install and tested unit. • Lower selection, ordering, installa tion and commissioning costs.
In the support portal, you will find information about products and services.
Manual valve overrides . Profibus-DP. • CANopen. • CC-Link. Four strings with up to 32 inputs and. 32 outputs (version-dependent) can be connected to a fieldbus node or control block. . 1) Cannot be assembled in conjunction with the control cabinet version of the pneumatic multiple connector plate CPV10-VI-P..
CPV pneumatics manual. CPV valve terminal. Type CPV-VI. Manual. 165 200 en 0204f. Compact performance .. CPV10/14/18: – CANopen. – DeviceNet. – Honeywell SDS. – Interbus Local bus (only in sizes CPV10/14). – PROFIBUS DP, Festo field bus, ABB CS 31, Klockner-. Moeller SUCOnet K. These valve terminals
Electronics manual. CPV valve terminal with direct connection. Type CPV..?DI01. Field bus protocols: ? PROFIBUS?DP. ? Festo field bus. ? ABB CS31. ? SUCOnet K. Manual. 165 817 en 0503d. Compact Performance