10-55 Hz, 0.35 mm. Minotaur MSR127R/RP/T/TP/; MSR127.1TP. PN-387541, April 2011. Monitoring Safety Relay - Installation Instructions. Sicherheitsrelais - Installationsanleitung. Relais de securite de surveillance - Notice d'installation. Rele di monitoraggio di sicurezza - Istruzioni per l'installazione. Rele de seguridad de
Performance Level E, Categorie 4 according to EN ISO 13849-1; Stop categorie 0; 3 safety contacts; 1 auxiliary contact; Cross fault monitoring; Monitored or automatic reset; Removable Terminals; Perfect for Safety light curtains, E-stop or gate applications; MSR127 RP has a monitored manual reset; MSR 127 TP has an
Safety Relays. 4-5. Note: ? Auto./Man. = Automatic/Manual and Mon. Man. = Monitored Manual. Reset. ?. Output Switching. Current, A. Housing. Width. (mm) MSR127T. Automatic/Manual. 440R-N23124. MSR127R. Monitored Manual. 440R-N23127. Removable. 24V AC/DC. MSR127TP. Automatic/Manual. 440R-
3 N.O.. 1 N.C.. Removable (Screw). Monitored Manual. 24V AC/DC. 440R-N23135. 1 N.C., 2 N.C., Light Curtain. 3 N.O.. 1 N.C.. Removable (Spring Clamp). Auto./Manual. 24V AC/DC. 440R-N23132S. 1 N.C., 2 N.C., Light Curtain. 3 N.O.. 1 N.C.. Removable (Spring Clamp). Monitored Manual. 24V AC/DC. 440R-N23135S.
MINOTAUR. MSR127R-MSR127T. MONITORING SAFETY RELAY. UBERWACHUNGS-/SICHERHEITSRELAIS. RELAIS DE SECURITE POUR CONTROLE. Einbauanleitung. (b) Installation Instructions. Notice D'installation. RETAIN THESE INSTRUCTIONS. Installation must be in accordance with the following steps and
MSR127TP. Light Curtain, Monitored Manual Reset, Monitored Output. Single Channel E-Stop, Automatic Reset, No Output Monitoring. S11. S12. S52. S22. S21. S34 A2. A1. L1. N. 14 to connect to the system. Then move to the right according to the number of non-OSSD input devices you need, such as 1 N.C. or 2 N.C..
light curtain must perform the cross fault detection. The MSD127DP has a monitored manual reset. The MSD127TP has an automatic/manual reset. Models with automatic/manual reset can have the reset jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop.
The MSR127RP relay has a monitored manual reset whereas the MSR127TP relay has an automatic/manual reset. Models with automatic/manual reset can have the reset jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring loop. Models with monitored manual
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation,. Inc., is prohibited .. The CI safety relay is compatible to the MSR127 safety monitoring relay. The. CI safety relay read from these relays and transferred to other devices over EtherNet/IP with the catalog