Saturday 17 March 2018 photo 10/15
|
Scxi 1314 manual dexterity: >> http://jlu.cloudz.pw/download?file=scxi+1314+manual+dexterity << (Download)
Scxi 1314 manual dexterity: >> http://jlu.cloudz.pw/read?file=scxi+1314+manual+dexterity << (Read Online)
This document contains information and step-by-step instructions for verifying the value of the shunt-calibration resistors, the value of the quarter-bridge resistors, and the performance of the temperature sensor on the National Instruments SCXI-1314 terminal block.
socketed 350 ? quarter-bridge completion resistor in the SCXI-1314 terminal block. A 120 ? quarter-bridge You do not need to manually adjust a potentiometer. By removing this offset through the that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training.
SCXI-1314. –. Quarter-bridge completion/shunt resistor. SCXI-1540. SCXI-1315. –. –. SCXI-1581. SCXI-1300. –. –. 1Cold-junction compensation (CJC) sensor for thermocouple measurements. 2Recommended for thermocouples; includes isothermal design and high-precision. CJC sensor. 3Recommended for RTDs when
module, refer to the SCXI-1520 User Manual. What You Need to Get Started. To install and use your SCXI-1314 terminal block, you need the following items: ? SCXI-1314 terminal block. ? SCXI-1314 Universal Strain Terminal Block Installation Guide. ? Eight precision 120 ? resistors for use in quarter-bridge completion.
Overview. The National Instruments SCXI-1314T is a front-mount terminal block for the SCXI-1520 bridge input module. It is compatible with any Class 2 TEDS (Transducer Electronic Data Sheet) bridge-based sensors as well as voltage-output sensors (up to ±10 V). The NI SCXI-1314T plugs directly into the front of the
The SCXI-1314 is a front-mounting terminal block for the SCXI-1520 universal strain gauge input module, for use with 350 Ohm quarter bridge strain gauges. This terminal block includes a factory installed and socketed 350 Ohm quarter-bridge completion resistor for each channel. Eight 120 Ohm resistors are included, but
SCXI-1314. –. Quarter-bridge completion/shunt resistor. SCXI-1540. SCXI-1315. –. –. SCXI-1581. SCXI-1300. –. –. 1Cold-junction compensation (CJC) sensor for thermocouple measurements. 2Recommended . With a front-panel trimming potentiometer, you can manually null out the offset voltage of bridge transducers.
berg, Kjellberg, & Lindbeck, 1995; Kihlberg,. HFSXXX10.1177/0018720813485977Month XXXX - Human FactorsLinear Modeling of Hand-Arm Dynamics . and damping with respect to skill in sports perfor- mance (Tsuji, Takeda, & Tanaka, SCXI-1314 devices were used for simultaneous data acquisition (DAQ) from the
This document is disseminated under the sponsorship of the New Hampshire Department of. Transportation (NHDOT) and the U.S. Department of Transportation Federal Highway. Administration (FHWA) in the interest of information exchange. The NHDOT and FHWA assume no liability for the use of information contained
Annons