Sunday 11 March 2018 photo 7/15
|
Metaglene guide: >> http://fgc.cloudz.pw/download?file=metaglene+guide << (Download)
Metaglene guide: >> http://fgc.cloudz.pw/read?file=metaglene+guide << (Read Online)
cementless metaglene
metaglene glenosphere
depuy global unite surgical technique
depuy delta xtend metaglene
depuy delta xtend recall
depuy total shoulder technique guide
metaglene screw
metaglene definition
4. Superior Lateral Approach. 5. Humeral Head Resection. 6. Humeral Reaming. 7. Distal Humeral Reaming (Revision Surgery). 8. Proximal Reamer Guide Assembly. 8. Proximal Humeral Reaming. 9. Trial Humeral Implantation. 10. Exposure of the Glenoid. 10. Preparation of the Glenoid. 11. Implantation of the Metaglene.
Superior-lateral Approach. Delto-pectoral Approach. 3. Metaglene Central. Peg Drilling. 2. Cannulated Glenoid Reaming. 1. Choice of Optimal. Metaglene Positioning. Glenoid Surgical Steps. Modular Implant. Cementless Technique. Monobloc Implant. Cemented Technique. 3. Proximal Reaming. Guide Positioning
27. 8. Surgical technique Affinis Fracture Inverse. 8.1 Glenoid preparation and Metaglene implantation. Mount the Holding / Rotation Rod onto the Metaglene Drill. Guide.Use the Metaglene Drill Guide to position the central. Kirschner Wire. The inferior border of the guide must be flush with the inferior border of the glenoid.
DELTA XTEND hemi-shoulder replacement system is also indicated for hemi-arthroplasty if the glenoid is fractured intraoperatively or for revision of a previously failed DELTA XTEND Reverse Shoulder. The metaglene component is HA coated and is intended for cementless use with the addition of screws for fixation.
Humeral Surgical Steps. 3. proximal reaming guide positioning. 1. Approach. 2. humeral head resection. Modular Implant. Cementless Technique. Monobloc Implant. Cemented Technique. 1. Approach. Delto-pectoral. Approach. 2. humeral head resection. 1. choice of optimal metaglene positioning. 2. Wire guided glenoid
Slide the 27 mm glenoid resurfacing reamer onto the central guide pin and ream manually. Use the metaglene reamer carefully to avoid any inadvertent fracturing of the glenoid, especially if the glenoid is sclerotic. The reamer is also power compatible, but CTA glenoids often are too soft for power. This reamer prepares a
guide positioning. Delta Xtend™ Key Surgical Steps. Humeral Surgical Steps. 2. Humeral head resection. 1. Approach. Monobloc Implant. Cemented Technique. 2. Humeral head resection. 1. Approach. Superior-lateral Approach. Delto-pectoral Approach. 3. Metaglene central peg drilling. 2. Wire-guided glenoid reaming.
Metaglene Positioning. Glenoid Surgical Steps. Modular Implant. Cementless Technique. 4. Determination of the Epiphysis. Size and Eccentricity. Standard Option. Eccentric Option. 3. Proximal Reaming. Guide Positioning. NOTE: The GLOBAL™ APG+ Shoulder System Access. Reamer 40 may be used as an alternative
If sufficient peripheral depth is not achieved, the glenosphere will not fully engage with the taper on the metaglene, and further reaming should be carried out until the tray is fully seated. Mark the major and minor axes of the glenoid using diathermy. Attach the 1.5 mm guide pin to the power tool and create an entry point just.
Reverse shoulder arthroplasty includes 2 glenoid components: the Metaglene® which is usually attached with a central peg and screws to the scapula and the Humeral head resection is performed using a cutting guide that is specific to each prosthesis and may be different depending upon the surgical approach but is
Annons