Take note of safety instructions for Ex applications. Please note the Ex specific safety information which you can find on our homepage www.vega.com/downloads under "Approvals" and which comes with every instrument. In hazardous areas you should take note of the corresponding regulations, conformity and type
View and Download Vega DIS 81 operating instructions manual online. External display and adjustment unit for plics sensors. VEGADIS 81 Accessories pdf manual download.
Supplied by. Call us on +44 (0)118 916 9420 | Email info@247able.com .com. Installation & Maintenance Instructions. VEGADIS 81 EXTERNAL. DISPLAY AND ADJUSTMENT. UNIT, PLASTIC HOUSING
Vega VEGADIS 81 Pdf User Manuals. View online or download Vega VEGADIS 81 Operating Instructions Manual.
These instructions are attached as documents to each instrument with Ex approval and are part of the operating instructions manual. Editing status: 2015-06-29 VEGADIS 81 • 3 1 About this document 1 About this document 1.1Function This operating instructions manual provides all the information you need for mounting,
VEGADIS 81 •. 43814-EN-130502. 1 About this document. 1.1 Function. This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instruc- tions for maintenance and fault rectification. Please read this informa- tion before putting the instrument into
1 About this document. VEGADIS 81 •. 43814-EN-170913. 1 About this document. 1.1 Function. This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instruc- tions for maintenance, fault rectification, the exchange of parts and the safety of the user.
Application area. Remote measurement value indication and adjustment of plics® sensors. The VEGADIS 81 is an external, digital display and adjustment unit for all plics® sensors. The instrument is mounted in a distance of up to 50 m away from the sensor where it is easily accessible. It is directly connected to the
The VEGADIS 81 is an external measured value indication which is also used for sensor operation. It can be mounted at a distance of up to 50 m from the sensor and is powered directly by the sensor. Sepa- rate external energy is not required. If the sensor is difficult to access, the VEGADIS 81 can be mounted at an
The VEGADIS 81 is an external, digital display and adjustment unit for all plics® sensors. The instrument is mounted in an easily accessible position up to 50 m away from the sensor. It is directly connected to the sensor electronics and also powered by it. Your benefit. • Measured value indication and sensor adjustment in