Designation: D 3278 – 96 (Reapproved 2004)e1. Flash Point of Liquids by Small Scale Closed-Cup. which a material does flash when using a small scale closedcup apparatus.2 The test methods are applicable to paints,
D3278 - 96(2011) Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus , flash/no flash, flash point, organic peroxides, organic solvents, small scale closed-cup apparatus, Butanol (sec/tert/n), Closed-cup flash point methods, Flash point--liquids, Lacquer, Organic peroxides, Setaflash
Automatic barometric correction. The automated Pensky-Martens flash point tester accurately determines the lowest flash point temperature of fuels, lubricating oils, and homogenous liquids (ASTM D93 A), or liquids containing suspended solids as well as liquids that tend to form a surface film during testing (ASTM D93 B).
There are 4 major “closed cup" flash point tests which are specified nationally and internationally for testing fuels and other materials: Pensky-Martens, Small Scale (rapid equilibrium), Abel and Tag. The Small Scale Closed Cup test is specifically identified by the following test methods: ASTM D3278, ASTM D3828, IP303,.
This test method is under the ioint iurisdiction of ASTM Committee D-2 on. Petroleum Products and D 3828, D 3278, and D, 3941. 1.4 The values 2.1 ASTM Standards: D93 Test Methods for Flash Point by Pen&y-Martens. Closed Cup Tester3. D 850 Test Method for Distillation of Industrial Aromatic. Hydrocarbons and
Setaflash Small Scale Flash Point. Setaflash Series 2 Closed Cup Tester. ASTM D3278; D3828; ISO 3679; 3680; CFR 173.120; EPA 1020 A & B. Safe, simple, highly cost effective flash point testing
23 Nov 2010 ASTM D3278-1996 - Designation: D 3278 – 96e1 Standard Test Methods for Flash Point of Liquids b
Setaflash Closed Cup Tester, using the test method specified in ASTM Standard (D3278-96 (2004)e1 .. ASTM D4978-95(2007)10 test methods are applicable to the screening of reactive sulfides in wastes, liquids, sludge's .. is available on the web at: www.epa.gov/epawaste/hazard/testmethods/sw846/pdfs/1050.pdf.
See American Society for Testing Materials (ASTM) Standard D 3278-78 for these method procedures used in the characterization of the flash point of liquids. This standard is one of three required method options for determination of the ignitability characteristic in liquid wastes, see 40 CFR 261.21(a)(1). Currently, this
Q. Which SETAFLASH is best for my requirements? 1) How many samples do you need to test per day? Series 3 is a manual test instrument and designed for low test throughput of typically no more than 10 samples per day. For volume sample testing the automatic Series 8 instrument is recommended. 2) Gas versus