three phase dol starter wiring
2-Phase and 3-Phase, Size 00 to 5. 44. 3-Phase, Size 6. 45. 3-Phase, Size 7. 46. 3-Phase Additions and Special Features. 47-50. Integral Self-Protected Starters . 51-57. Integral 18 State of Auxiliary Contacts. 51-52. Integral 32 and 63 State of Auxiliary Contacts. 53-54. Wiring Diagrams. 55-57. Type S AC
To start and stop a three phase induction motor by Direct On Line (DOL) Starter. larger sizes use an electromechanical contactor (relay) to switch the motor circuit. Control Circuit. Fuse. Fuse. Overload. C.B. C.B. Contactor. Coil. Pushbutton. Pushbutton. Power and Control circuits connections diagram. 5- Procedure a.
Wiring to overload: ? Connect leads provided from – terminal 14 to terminal 95 and terminal A2 to terminal 96. ? Check operating coil voltage and frequency Trip within 4 minutes. 7.2 x FLC. Trip between 4s and 10s. NOTE: FLC = Full load current. 1. T. V. S. 0. 1. 3. 1. 1. 4. P. 0. 3. 0. 0. R e v. 1. 0. 1. /1. DOL Starter.
600VAC, 3-phase. More Horsepower in a Smaller (45mm) Frame. CWC series mini contactors are a complete solution for controlling motors and switching other A1. A2. Contactor/Control Relay Coil. IEC Schematic Symbols. Timing Diagram. IEC Wiring Diagram. Note: Right side mounting. Coil. Start Output. Connection.
For control circuit between phase and Neutral (240V) of a three phase line, remove connection 5 and connect Neutral to terminal A1. For 56DOL. online starter. • Field power wires are shown in heavy dashed line. Wiring Diagrams. Direct online Starters. Diagram 1. For two wire control the control lines. (shown in dashed
Typical circuit diagram of Direct On Line starter a) Main circuit b) Control circuit for momentary-contact control c) Control circuit for maintained-contact control. Typical Typical circuit diagram for Auto Transformer starter. Internal connection diagram for DC coil circuits. K1 : Sizes 3 to 6,. 3TF46 to 3TF51. K1 : Sizes 8 to 12.
Neutral Block. Contactor. 415VAC 3 phase supply. Simple 240 VAC Control DOL Start Circuit. Using The Overload Stop Button. – = Control wiring. 240VAC Coil. Stop button on overload. 3 Phase
Page 1 of 3. EDS1001-001. Selecting the correct starter. Various factors should be considered when select- ing the correct DOL. Firstly the type of environment and mounting position will decide the enclosure material - Either steel of plastic. The size of unit is dictated by the motor that is being supplied and can be selected
Eaton Wiring Manual 06/11. 8-1. 88. All about Motors. Page. Motor protection. 8-3. Notes on engineering. 8-15. Circuit documents. 8-19. Power supply. 8-21. Control circuit supply. 8-24. Contactor markings. 8-25. Direct-on-line start of three-phase motors. 8-26. Control circuit devices for direct-on-line start. 8-34. Star-delta