dean pump curves
dean pump r434
dean pump r434 manual
dean ra3146 manual
dean pump 3146
ra2096
dean pump distributor
dean centrifugal pump
each Dean Product. RA SERIES. FAN COOLED, HORIZONTAL, SINGLE STAGE, END SUCTION, ENCLOSED IMPELLER, CENTRIFUGAL HOT OIL PUMPS. (temp. within 12" of pump). 104?F. 118?F. 118?F. Hydrostatic Test Pressure. 430 PSIG. 550 PSIG. 550 PSIG. Part No. Part Name. RA2096. Class 22. RA3146.
growth at higher pumpage temperatures allowing foot type construction. • Dimensionally interchangeable with small ANSI B73.1 pumps. Dean Pump® RA3146. The larger, centerline mounted version of the air-cooled RA series pumps. • Available in nine sizes. • Dimensionally interchangeable with R4140 Series.
Global Pump Solutions. DO NOT INSTALL, OPERATE, OR SERVICE THIS PUMP. BEFORE READING THE ENTIRE MANUAL. DEAN PUMP. ® SERIES PH/PHP .. 125 Ra. Stuffing box jacket pressure maximum. 125 psig 125 psig 125 psig 125 psig 125 psig. Bearing housing cooler pressure maximum. 125 psig 125 psig
9 Oct 2017 Download >> Download Ra3146 service manual. Download >> Download Ra3146 service manual met pro pumps dean pump distributor dean pump r434 ra3146 pump. Read the instruction manual completely before installing, filling, operating, or . RA3146. RA3186. Direction of Rotation. (Viewed from
Bulletin C 1.4.45. RA2000/RA3000. RWA. RMA5000. R400/R4000. Dean Pump Division. R Series. High Temperature Pumps . RA3146 PUMPS. RA2096 PUMPS. Working Pressure vs Pumping Temperature. Air-Cooled High Temperature. Thermal Liquid Pumps. • Capacities to 1,100 GPM (250 m3/hr). • Heads to 425 feet
Dean Pump Division Bulletin C 1.4.42 High Temperature Air-Cooled Hot Oil Pumps RA2096 RA3146 No Water Cooling Required RA3186. Open the catalogue to page 1. RA2096 The smaller, foot mounted economy version of the air-cooled RA series pumps. • Available in three sizes. • Bearing is double row thrust bearing,
oughly qualified personnel in strict accordance with this manual and must comply with all local, state and Federal codes. Only Dean authorized service parts must be used . ra tu re. Lim it - 2. 0. De g. F . W o rk in g. Pre ss u re. - P .S .I.G . W o rk in g. Pre ss u re. - K. Pa. Seal Chamber Temperature VS. Pumping Temperature.
The RA Series Pumps are cost effective, hot oil, thermal liquid, heat transfer pumps that feature a shaft mounted fan to provide air flow over the cooling fins of the pump. This air cooled design translates to NO WATER COOLING REQUIRED for the bearings and mechanical seals. Thirteen sizes are available in ductile iron
The RA3146 and RA3l86 have ball bearings that are hand packed as an assembly procedure when the pump is Grease is also available from Dean Pump in individual containers. One container is required for a RA3Mo pump. . 4) Give complete shipping instructions. TYPE RA PUMP PARTS. 56. 77B 28 76A. Denotes